operation manual
42 43
DeutschEnglish
DeutschEnglish
In the following, please find a selection of the most important instructions for operation
of Power 26-104 battery. Beside these, please also observe complete operating manual to
prevent any damage to the battery.
• Onlyuseequipmentthatdoesnotdrawmorethan180ampsfromonebattery(at
nominal voltage corresponding to 4,660 watts). In case of batteries connected in parallel
you may draw 180 amps from each connected battery (in case of 2 batteries connected
in parallel, this corresponds to a withdrawal of 360 amps or 9,320 watts). Higher con-
sumption will trigger the electronic fuse. After elimination of overload, battery may be
switched on again.
• Insurecorrectpolaritywhenconnectingequipmentandchargers.
• Youwillextendbattery‘sservicelifeifyoudoneitherexposeitdirectlytothesunnorto
high ambient temperatures longer than necessary. When stored for a longer period of
time, battery should have a residual charge of 20-40 %. Regularly check voltage so that
it is always higher than 21 V in order to prevent total discharge. Drawing on page 52 will
help you to precisely define your checking intervals.
• Idealbatterystoragetemperatureisbetween5°and15°C/41°Fand59°F.
WATCH OUT
This symbol warns about possible risks of damage caused to or
injuries caused by the battery.
2. Information required by law
2.1 Identification and technical data
Please find type plate exhibiting complete product description at the spot shown in the
figure.
Date of inspection
or disposal
SerialNumber
Battery identification code
(stored in the battery
electronics)