operation manual

Table Of Contents
Error messages
EN DE
Display Cause What to do
E33 General communication error Check the plug connections on the cables.
Check the cables.
Clean the contacts using contact spray.
Switch the motor off and on again.
E41/ E42 Incorrect charging voltage If this error occurs despite the use of a Torqeedo power supply unit, con-
tact Torqeedo Service.
E43 Battery flat Charge the battery. It may be possible to restart the motor slowly from the
neutral position.
E45 Battery overcurrent Switch the motor off and on again. The battery has switched off due to ex-
cessive current draw. Check whether the propeller rotates freely. Contact
Torqeedo Service.
E46 Battery operating temperature error Battery cells are outside the operating temperature range of -20 °C to
+60 °C. It is possible to operate the motor again after the temperature has
stabilised.
E48 Charging temperature error Let the battery cool down. Charging continues when the cell temperature
is between 0 °C and +45 °C.
Other error codes Defect Contact Torqeedo Service and provide error code. Check power source,
main fuse, and main switch.
If power supply is working correctly: Contact Torqeedo Service.
Nothing is shown on display If power supply is working correctly: Contact Torqeedo Service.
page 95 / 112