operation manual

DeutschEnglish
5.6 Error messages/trouble shooting
59
Display Cause What to do
E02 Stator over-temperature
(motor overheating)
Motor can be used again after a short wait about 10 mi-
nutes). Contact Torqeedo Service.
E05 Motor/propeller blocked Disconnect motor cable from battery, then loosen blockage
andturnpropelleronerevolutionbyhand.Reconnect
motor cable.
E06 Voltage in the motor too
low
Low battery charging status. Motor can potentially be used
again slowly from the stop position.
E07 Motor overcurrent Continue at low output.
E08 Circuit board overheating Motor can be used again after a short wait about 10 mi-
nutes). Contact Torqeedo Service.
E21 Tiller calibration defective •Re-calibrate:Press“cal”buttonfor10seconds.
•Thedisplayshows“calup”:Presstillerforwardtofull
gasthenpressthe“cal”button.
•Thedisplayshows“calstp”:Returntillertocentralposi-
tionthenpressthe“cal”button.
•Thedisplayshows“caldn”:Presstillerbackwardtofull
gasthenpressthe“cal”button.
E22 Magnetic sensor defective Re-calibrate(refertoE21)
E23 Value range false Re-calibrate(refertoE21)
E30 Motor communication
error
Checkthemotorcable’splug-inconnection.Checkthe
motor cable for damage.
E32 Tiller communication error Check the tiller‘s plug-in connections. Check the cable.
E33 General communication
error
Check the plug-in connections and cables. Switch the
motor off and on again.
E41, E42 Incorrect charging voltage Use a Torqeedo power supply. If the error occurs in spite
of using a Torqeedo power supply, wait untill the battery
dissipates the overcharge. Should the error persist please
contact Torqeedo Service.
E43 Battery empty Charge battery. Motor can potentially be used again slowly
from the stop position.
E45 Battery overcurrent Switch motor off and on again. If this error occurs the
battery status indicator and range display can no longer
operate until the battery has been fully charged again.
E46 Battery operating tempe-
rature error
Batterycellsoutsideoperatingtemperaturebetween-20°C
and+60°C(-4°Fto140°F).Themotorcanbeusedagain
when the temperature has stabilized.
E 48 Charging temperature
error
Charging will continue when the cell temperature is
between0°Cand+45°C(32°Fto113°F).
Other error
codes
Faulty Contact Torqeedo Service and notify them of the error
code.
No blinking
during charge
process, no
function of tiller-
display during
charge process
Faulty Contact Torqeedo Service.