Quick Start Manual
4.  Route the wire cable into the timer through the 
large opening in the base of the housing or 
through PVC conduit (if installed). Strip insulation 
back 3/8
″ (10mm) from all cable wires.
  Note: The zone modules have quick-release wire 
terminals. To attach wires, simply raise the lever, 
insert the stripped wire, and press the lever down 
to secure.
5.  Secure the valve common wire to the terminal 
labeled COM. Connect the individual zone valve 
wires to the appropriate zone module terminals. 
Connect the master valve wire (if applicable) to 
the terminal labeled PUMP/MV. 
 Connecting a Pump Start Relay
Note: Connecting a master valve or pump start relay 
is optional and may not be required for your sprinkler 
system.
CAUTION: To prevent timer damage, do not 
connect the timer directly to the pump starter. 
A 24 VAC, 0.3A (max) relay must be used.
1.  Route wire pair from the 24V relay into the timer. 
2.  Connect one wire to the terminal labeled COM. 
Connect the remaining wire to the terminal 
labeled PUMP/MV.
CAUTION: 
To prevent pump damage due to 
back pressure, remove all unused zone modules. 
Connect a jumper wire from an unused zone 
terminal to a terminal with a valve connected.
 Connecting the Plug-in Transformer
CAUTION: Do not plug the transformer into an 
electrical outlet until all of the wiring procedures 
have been completed.
1.  Route the cable from the transformer through the 
small opening in the base of the housing.
2.  Connect one cable wire (in either order) to each 
terminal labeled 24 VAC.
  Note: The display will begin flashing 12:00 am. 
Press any button to halt flashing. 
3