Quick Start Manual
  Indoor Timer Installation
IMPORTANT: 
The ECXTRA Indoor model is 
not weather resistant and must be installed in a 
sheltered area. 
1.  Select a location for the timer within 4
′ (1.2m) 
of an electrical outlet. Make sure the outlet is 
not controlled by a light switch.
2.  Remove the mounting bracket from the back of 
the timer housing by pulling the lower edge of the 
bracket away and down from the timer housing.
3.  Place the mounting bracket against the wall, 
aligning the top edge at about eye level. Secure 
the bracket using the two stainless steel screws 
provided, or use appropriate screw anchors if 
installing on drywall or masonry.
  Note: If optional valve wiring conduit is preferred, 
insert 3/4
″ (19mm) PVC conduit into the sleeve 
provided on the bottom edge of the bracket.
4.  Align the slotted openings on the back of timer 
housing with the mounting bracket tabs. Slide the 
timer downward to engage the tabs.
  Note: Store the Quick Start guide in the pocket 
formed between the timer and mounting bracket.
  Connecting the Valves
1.  Route the valve control wires between the valves 
and the timer.
  Note: The snap-in wire connectors accept 14 
to 18 gauge wire. Using 18-gauge, multi-strand, 
direct-burial irrigation cable is recommended. 
Choose a cable that has at least one more 
wire conductor than the number of valves to be 
connected.
2.  Attach the white color-coded wire to either one of 
the wires from 
each valve solenoid. This is called 
the valve common 
wire.
3.  Attach an individual color-coded wire to the 
remaining wire from each valve solenoid. Make a 
note of the wire color used for each valve and the 
watering zone it controls. You will need to have 
this information when connecting the valve wires 
to the timer.
CAUTION: Use Toro waterproof wire 
connectors (Model # 53687) or grease caps 
on all exposed wire connections to prevent 
corrosion, connection failure and short circuit. 
2