Control Manual

26
Error Solution
Valve 1. Check station times and water budget.
stays on
2. Check for Manual mode; place dial in
Run
position
.
3. Disconnect valve wire. If still on, valve
malfunction is indicated.
4. Check for manual bleed closure at valve.
Valve will 1 . Ensure dial is not in Rain Off position
not turn on or Rain Delay mode active.
2. Verify program: station time, watering start
times, watering days schedule, current time,
current day and water budget.
3. Make sure common wire and valve wire are
correctly connected.
4. Check for a shorted station, refer to page 5.
5. If using sensor, check sensor.
6. Check for blown fuse. Replace if necessary.
See page 27 for fuse replacement information.
“Short” or 1. See “How the Electronic Circuit Breaker
“Master Valve” Works” on page 5 for troubleshooting
is displayed information.
Waters too 1. Too many program start times set. Check
often each program to determine the number of
start times assigned and remove as necessary.
Troubleshooting