System Guide

3. The example below shows Soil Data Station and Station Mapping columns
hidden from view.
Note-EICON special-build wireless system only: The Setup Wireless,
and Learn Current buttons in addition to the Nominal and Actual Current
data column are applicable to EICON wireless communication system
setup only.
(Requires satellite firmware version 2.43 or higher.)
Using the Multi-Station Editor
The Zone Data column headings are organized within the Multi-Station
Editor panel. Station setup information is entered in the Editor text fields,
then transferred to a selected station or selected group of stations.
1. Choose Hide/Show Editor button on the Zone Data toolbar to display the
Multi-station Editor panel.
2. Enter a brief Station (Stn) Description and/or Type Description enabling
the station to be easily identified using the Station Search feature.
3. Choose the Station Type from the list-menu options. (Requires satellite
firmware version 1.41 or higher.)
4. Enter the Expected Flo
w
r
ate of the station.
5.
Enter the Maxim
um Flow
r
ate
allo
wed for the station (alarm threshold).
6. Enter the
Plant Factor value from 0–255% (where 100% represents the
ET total value). (Required for ET-based run time calculations.)
7. Enter the Precipitation Rate value from 0–99.9 Inches/Hour.
(Required for ET-based run time calculations.)
8. Enter the Soil Infiltration Rate value from 0–99.9 Inches/Hour.
(Required for ET-based run time calculations.)
9. Enter the Water Holding Capacity value from 0–2.55 Inches.
10. Enter the
MapTo data Unit and Station numbers as applicable.
11. Using standard shift-click or ctrl-click keyboard commands, select all
station numbers to be edited simultaneously.
12. Edits can also be made for a specific column heading by dragging the
column heading box into the gray edit field as shown in the example
below.
Note: To revert to the default view, click and drag the column header out of
the gray field. Release the mouse button when the pointer changes to an X.
13. Identify the Editor column data to be transferred by selecting its check box.
The selected field color will change to yello
w as shown the example above.
14. Choose Apply Checked Columns button to transfer the data.
1
1
5
5