User's Manual

7
II. Programming Overview & Navigation
e Sentinel Controller is programmed by navigating through a Main Menu which includes seven submenus: Manual Watering,
Scheduled Watering, Diagnostics & Alarms, Station Settings, Help, Stop, and Satellite Settings. Each of these submenu options has sys-
tem conguration options. e menu structure is detailed below.
Menu Setting Function
Manual Watering Manual
Start/Stop Program
Turn individual stations ON or OFF for a specic time.
Start and stop programs.
Scheduled Watering Start Times
Prog ET Toggle
Clear Schedule
Schedule Length
Run Days
Program Clear
Rain O Days
Assigned Sched
Water Window
Continuous Run
Repeat Dly (Delay) Time
Repeats
Percent Scale
Slot-Stn-Time
Schedule the time for individual stations to activate, by program.
Program individual programs (up to 16) to use ET data or not.
Clear schedules of programs, one at a time.
Set the length of a schedule to run per schedule: six weeks or one year.
Specify which days per week a schedule should irrigate, by week, by schedule.
Clear a particular program. Note: ere is no conrmation before clearing.
Enter “Rain O” days by program, up to 255 days. What is this for?
Assign schedules to programs or vica-versa.
Dene “water windows” by program--watering only occurs between specied times.
Activate a program to run continuously.
Places a delay period, ranging from 0 to 255 minutes, between program repeats.
Enables the watering cycle to be repeated from 1 to 250 times per start time.
Adjust watering time by % of programmed time. Useful for seasonal adjustments.
For a complete description of this command, see page 23.
Diagnostics & Alarms Show Alarms & Warnings
Clear Sat. Alarms
Clear Comm. Alarms
Clear Elec. Alarms
Clear Flow Alarms
Show Moisture Data
Show the cause of an “Alarm” ashing light.
Clear any and all Satellite alarms.
Clear any and all Communication alarms.
Clearl any and all Electronic alarms.
Clear any and all Flow alarms.
A moisture sensor must be installed for this command to work.