Precipitation Rate (2 Fields to set: Station number and precipitation rate)
is is the amount of water a zone applies in inches per hour. For example, a zone of xed spray heads may apply the water at the rate of 2”
per hour while a rotary sprinkler zone may apply water at the rate of 0.50” per hour.
It is possible to determine a zone’s application rate by multiplying its gallons per minute by 96.3 and dividing that gure by the square feet
covered by the zone.