User's Manual
34
BASELINE Set AAA/BBB:CC = 000/001:xx where xx is decoder address.
We set BBB = 001 (address of Baseline gateway connected to Sentinel serial port). CC decoder address
maps to a specic physical decoder (serial number) in the Baseline Setup Software.
Station Type (2 Fields to set: Station number and station type)
e following station types are available:
UNIVRSAL – Use this option to turn on outputs locally and on a universal map to (when mapped). (is is the default option.)
LOCAL – Use this option to turn outputs on locally (out the front of the satellite).
TMC-424 – Not currently utilized. Toro TMC-424 Controller.
BL-FL/PR – Not currently utilized. Baseline Flow & Pressure.
BL-SENS2 – Not currently utilized. Baseline Sensor.
BL-SENS2 – Not currently utilized. Baseline Sensor.
BASELINE – Use this option to turn output on locally and on Baseline two-wire system.
WIRELESS – Choose this option to run outputs on a wireless output board.
TORO-2WD - Use this option to turn output on locally and on Toro two-wire system.
WIRELESS-LR (long range) - Allows operation of wireless output boards via a long range radio connected to one of the Sentinel
satellite’s external serial ports.
2 3 41
ENTER
- OR -
ENTER
- OR -