Flow Processing (1 Field to set)
Turn Flow Processing ON to monitor the ow of water to make sure ow is within limits determined by the irrigation zones running. If the
ow is not within the limits, Sentinel will take user-dened action to identify and label problems.
Note: For the controller to read and react to ow, a ow meter must be connected to the satellite sensor terminals. Do not turn on ow processing if it
is not properly set up.
Flow Factors Meter 2 (4 Fields to set: K and Offset X whole and decimal values)
Flow factors are the K and oset for each meter, used to determine the ow rate in gallons per minute or liters per minute from the raw pulse
rate of the meter. Flow factors are determined by the pipe size and type.
Enter/edit the K factor associated with the ow metering device being used. e K factor and Oset factor may be found in the
Specication sheet for the ow meter.