Owner's Manual
If you select Include Run Time Report in the AutoComm window before polling alarms, you can also open the Run Time
and Deviation Report by clicking the corresponding command buttons in the Alarms result window. The run time report
includes a listing of data similar to that displayed in the Run Time Report accessed from the Master Control Panel in
Sentinel. The Deviations Only report is a condensed version of the same data listing, excluding the programs that ran
normally as programmed and expected, so that results with deviations can be printed efficiently. See Appendix B for
specification and examples of these files.
You can launch Sentinel from the Alarms Results window in two ways. The square Sentinel button at the lower right corner
is a quick shortcut. Additionally, clicking one of the color-coded field unit boxes will open Sentinel in a special mode. This will
cause Sentinel to automatically open the Alarm Status window for that unit and retrieve the current alarm states of that unit.
You can set AutoComm to page you when it receives an alarm if you have a
pager. After selecting Poll Alarms in AutoComm, click Page to open the
utility window. You can enter a pager number and select the Comm Port and
other settings for the PC modem you will use to call the pager. You can also
adjust the delay after dialing and between pages, and specify the information
included with the page. Click the check box next to the alarm type to include
it in paging (if no boxes are checked, no paging will occur). You can enter
any string (text message that the pager will accept) in the text box, next to
the alarm, that you would like to include in the page message for that alarm.
You can select Include Unit Code to include the 3-digit unit code with each
page and you can also choose to include the station number for the
Overflow and Current alarms.
Page Notification on Alarm Activation
Run Times Report
12 - 29
Toro Sentinel Central Software User’s Guide