Installation and Programming Guide

13
Program SETUP
For a watering program to operate properly, it must have a station(s) with a runtime and a specic date and time to
activate. The following program parameters can be dened and/or modied in the SET PROGRAM function:
Assign Station and Runtime to a Program
Assign Station Delay Time
Assign Program Start Time
Assign Looping Start Time
Assign Watering Day Schedule
- Exclusion Day
- Odd Day
- Even Day
- Interval Day
Assign Water Budget
Set Program – Assign Station and Runtime to a Program
Assign Station and Runtime to a Program
Step 1 – Turn the Function dial to the SET PROGRAM position.
Step 2 – Enter the program number (1–8) you want to create or modify. Press to activate your selection.
Step 3 – Enter the station number being added or modied in the program and press the button.
Entering a station number that exceeds the controllers station count will return an error message.
Step 4 – Enter the station runtime in MM (Minutes) or HH MM (Hours:Minutes) and press .
Repeat Steps 3–4 for additional stations and runtimes.
To assign similar runtimes to all the available stations in the program, press , , Length of runtime,
then . This procedure will replace all station runtimes to the new runtime.
Delete a station from the program by assigning 00 runtime.
Step 5 – Return the Function dial to the Auto Run position to exit SET PROGRAM.