Installation Manual
Specifications:
• Controls up to 200 stations for the
Stand-Alone model
• Input power supply
100 VAC, 50/60Hz
120 VAC, 50/60Hz
240 VAC, 50/60Hz
• GDC output voltage: 40 VAC max.
• GDC output power: 98VA max.
• Storage temperature: -30C–60C
• Operating temperature: 0–60C
• Cabinet Type: Non-corrosive, lockable wall mount,
indoor/outdoor installation
• Six 25.4mm conduit openings and one 38mm conduit opening
Cabinet Installation
Selecting the proper installation site for the GDC is essential to safe
and reliable operation. The GDC features a weather resistant cabinet designed for indoor or outdoor installation.
The GDC should be installed on a vertical wall or other sturdy structure near
a grounded power source. Select a location that shades the controller during the
hottest hours of the day and provides as much protection from direct sunlight,
rain, wind and snow as possible. DO NOT mount the controller where it is
exposed to direct spray from the irrigation system.
For easy operation and better view of the display, install the GDC so that the
display is at or slightly below eye level.
Step 1 – Drill two pilot holes 15.25cm apart for the top keyholes of the
controller cabinet.
Step 2 – Install the top screws leaving approximately 5–6mm of exposed
screw to accommodate
the cabinet.
If mounting the cabinet on dry wall or
masonry, install the appropriate type of screw
anchors or fasteners to ensure secure installation.
Step 3 – Hang the cabinet using the top keyhole slots.
See
Figure 1.
Step 4 – Open the cabinet door and install the bottom two
screws to
secure the cabinet.
GDC 200 Stand-Alone Model
Installation Instructions
Figure 1
15.25cm
23.175cm