Data Sheet
SPECIFICATIONS
Operational
• Lynx
®
Central:
- Mapping capabilities
- Remote hand-held operation
- Weather station integration
- Pump station integration
• Enhanced diagnostics:
- Communication
- Electrical shorts/opens
- Solenoid check
• No holding power required to operate stations
• Decoder identification is a unique 5-character address
• Standalone option (GDC200)
Installation
• Maximum number of wire paths:
- 4 per gateway
• Maximum number of gateways:
- 4 per system (Standard)
- 9 per system (Remote)
• Maximum number of decoders per wire path:
- 250
• Maximum stations per gateway:
- 1000 integrated
- 1600 off fairway
- 1000 remote
• Maximum stations per system:
- 4000 integrated
- 6400 off fairway
- 9000 Remote
• Simultaneous stations per output board:
- 100
• Maximum distance from central to module
(using 14 gauge wire): 2.6 miles
• Maximum distance from module to sprinkler
(using 14 gauge wire): 400 ft.
• Solenoids per output: 2 DCLS-P
• Stations per module: 1, 2 or 4
Electrical
• Input power:
- 88-264 V ac, 50/60 Hz
• Output Power:
- Output voltage: 40 V ac max
- Output power: 75 VA max
- Class 2, SELV
• ISP 2-wire modules are rated at 20 KV surge protection
• 2-Wire modules wiring: 14 awg
Temperature
• Operating Temperature: 32° F to 140° F
• Storage temperature: -22° F to 212° F
GDC 2-WIRE CONTROL SYSTEM
www.toro.com / e Toro Company, Irrigation Division / 5825 Jasmine Street, Riverside, CA 92504 / 877-345-8676 / Specications subject to change without notice / ©2015. All rights reserved / P/N 15-5008-IG
Off Fairway Configuration
Integrated Configuration
DEC-ISP-4 DEC-ISP-2 DEC-ISP-1
Specifying Information— Gateway
DEC-XXX-XXXX
Type Communication Station Count
DEC XXX XXXX
DEC SA—Stand-alone
PCS—Central
RS—Remote*
200—200 Stations
1600—1600 Stations, Standard
1000-M—1000 Stations, Remote, Wired
1000-DR—1000 Stations, Remote, Radio
*1000-M & 1000-DR only
Specifying Information—2-Wire Modules
DEC-ISP-X
Type Configuration
DEC-ISP X
DEC-ISP—Module* 1—1-station 2—2-station
4—4-station
Example: A 2-station GDC Module would be specified as: DEC-ISP-2
*Refer to sprinkler pages for specifying information on Sprinkler 2-wire Modules