Software Guide

Pressingtheresetbuttonbringsupascreenaskingto
selectaresetoption.
Everytimeyouresetthehydraulictransmissionoil
servicereminder,themodulepromptsyoutoselect
whetherthemachinewasservicedwithT oroPremium
HydraulicOil.PressingY(yes)orN(no)determines
thecorrectmaintenanceschedule.
EngineOil
Afterperformingthenecessarymaintenance,this
screenallowsyoutoresetthenumberofhoursuntil
theengineoilserviceisdue.
g030245
Figure28
1.EngineOil
3.Remaininghoursuntil
service
2.Reminderdisplay4.Reset
Pressingtheresetbuttonbringsupascreenaskingto
conrmtheresetreminder.
HistoricalError
Thisscreendisplayserrorsthatarenolongeractive.
Thelogkeepsarunningcountofthenumberoftimes
theerrorhasoccurredduringthelifeofthemachine
andtheenginehouratwhichthelastoccurred.The
logdisplaystheerrorsstartingwiththemostrecent
occurrence.
g030224
Figure29
1.HistoricalError
3.Numberoftimestheerror
occurredduringlifeof
machine(e.g.,3X)
2.Currenterror(e.g.LowOil
Pressure)
4.Enginehouratwhichthe
errorlastoccurred
Alarms
Thealarmsscreenallowsyoutoactivateand
deactivatetheaudiblealarmforindividualerrors.
PresstheEnterbuttontoaccessindividualerroralarm
settings.
Note:Notallaudiblealarmscanbedeactivated.
g030225
Figure30
1.Alarms3.AudibleAlerts
2.Activate/Deactivate
4.Enter
Thehighlightederrornameindicatesthattheaudible
alarmisactive.Pressingentermodiesthestatusof
theaudiblealarmtoOnorOff.
g038366
Figure31
1.Alarms4.Toggle
2.ClutchOvercurrent
5.Enter
3.FuelLow
Youcandeactivatetheaudiblewarningforthe
followingerrors:
ServiceAirFilter
ServiceEngineOil
ServiceTransmissionOil
TransOverT emp
FuelLow
ClutchOvercurrent
ClutchResetRequired
EngineErrorCodes
SystemOvervoltage>16VDC
SystemUndervoltage<9VDC
SystemVoltageLow
Anti-Stall
11