Software Guide
g205520
Figure56
1.Previousandnextsection
icons(inactive)
3.Flowrate(e.g.,abovethe
0.500targetrate)
2.SectionOn/Officon(OFF
indicated)
4.Reducetheowindicator
(closethebypassvalve)
A.PressthesectionOn/Officon(Figure
56)toshutoffthesectionvalve(red).
B.Movetothebackofthemachine.
C.Adjustthebypassvalveatsectionvalve
1toreducetheowratetothetarget
applicationrate.
•Theapplicationrateforthesectionvalveis
toolow(Figure57).
Note:Inthisexample,thetarget
applicationrateis0.500gallon/1,000ft
2
butthemeasuredapplicationrateis0.472
gallon/1,000ft
2
.
g205524
Figure57
1.Flowrate(e.g.,belowthe
0.500targetrate)
2.Increasetheowindicator
(openthebypassvalve)
A.PressthesectionOn/Officon(Figure
56)toshutoffthesectionvalve(red).
B.Movetothebackofthemachine.
C.Adjustthebypassvalveatsectionvalve
1toincreasetheowratetothetarget
applicationrate.
5.TheSectionValveBalancedmessageappears
andthevalvebalancewizardwillautomatically
advancetothenextsectionvalve(Figure58).
g205523
Figure58
1.Sectionvalvebalancedmessage
6.Repeatsteps4and5forsectionvalves2
through10(Figure59).
25