Software Guide

FaultCodeTable(cont'd.)
FaultID
AffectedComponentor
System
DescriptionRecommendedAction
3
Mainpowerrelayfault
Themainpowerrelayisnot
supplyingcurrent.
4
Chargingsystemfault
Alternatorvoltageistoohighor
toolow.
14
SoftwareversionincompatibilityThesoftwareversionsare
mismatched
17
Startertimeout
Thestarterwasengagedtoo
long.
18TactionpedalneutralswitchThetractionpedalswitchdoes
notmatchgroundspeed.
CallyourAuthorizedT oro
ServiceDistributor.
19Flow-ratemeter
Thereisnosignalfromow-rate
meterwhenspraying.
Sprayinthemanualmode;Call
yourAuthorizedToroService
Distributor.
41
Sprayerpump-controlvalveTECcontrollerelectrical
problem.
CallyourAuthorizedT oro
ServiceDistributor.
Maintenance
ServiceScreens
1.ToaccesstheServicescreenpressbutton2
ontheMainMenuscreentonavigatetothe
SERVICEoption(Figure79);refertoAccessing
theMainMenuScreen(page3).
g192026
Figure79
2.Pressbutton4toselectSERVICEsub-menu
(Figure79).
Thisscreendisplaysandallowsyoutodisplay
hoursandowrateinformation.
ViewingtheServiceHours
1.Pressbutton1or2ontheServicescreenuntil
youreachtheHOURSoption(Figure80).
g192029
Figure80
2.Pressbutton4toselecttheHoursentry(Figure
80).
3.Usethecounterinformation(Figure81)
displayedonthescreentodeterminethe
following:
30