Software Guide

AdvisoriesTable(cont'd.)
ConditionCodeQualier
DisplayText
EngineStopped
103ParkingbrakesetEnginestopduetoparking
brakeengaged
PumpStartPrevented
202Boomactive
Tostartpump,turnboomsoff
PumpStartPrevented
203
Outofseatandparkingbrake
notset
Tostartpump,mustbeseated
orsetparkingbrake
PumpStartPrevented
204Pumpstartwhenvehicle
stopped
Tostartpump,movevehicle
PumpStartPrevented
205EnginestartingTostartpump,stopcranking
engine
PumpTurnedOff
206
Outofseat
Tostartpump,remainseated
Drivingprevented302Parkingbrakeengagedwhile
driving
Tocontinuedriving,release
parkingbrake
TankStatus
402LowspraytankvolumeTankstatus,volumelow
TankStatus
403RinsepumpactiveTankstatus,rinsepumpon
ParameterStatus
502WrongparametervalueenteredParameterstatus,invalidvalue
ParameterStatus
503
Avalueisoutsidetherangeof
acceptedvalues
Parameterstatus,invaliddata
defaultsused
BoomsTurnedOff
802
SpeeddroppedBoomsturnedoff,stoppedor
movingtooslowly
GeoLinkConguration
902
GeoLinkcontrollerconictGeoLinkConguration,check
GeoLinkcontrollers
GeoLinkConguration
903
InfoCentersettingGeoLinkconguration,check
InfoCentersettings
FlowRateMeter1002
NoowsignalFlowmeter,noowdetected
Neutralswitch1102NeutralswitchsignalNeutralswitch,motionwhilein
neutral
InfoCenterFaultCodes
FaultcodesdisplayontheInfoCenterscreenwhenthereisaproblemwiththeelectronicorcomputersystems.
Forexample,ifthefusefortheT oroelectroniccontrollerisopen,theInfoCenterdisplaysfaultcode1.Refer
tothefaultcodetableforalistfaultcodesandrecommendedactions.
FaultCodeTable
FaultID
AffectedComponentor
System
DescriptionRecommendedAction
1MasterToroelectronic
controller(TEC)
AsignaltoorfromtheMaster
TECareoutofrange.
CallyourAuthorizedT oro
ServiceDistributor.
2
OutputfuseAfuseforthemasterTECis
open.
Replacethefuse;refertothe
operatorsmanual.
29