Form No. 3414-228 Rev B Foam Marker Kit Serial number 400000000 and After Multi Pro® 1750, 5800, and WM Turf Sprayer Model No. 41249—Serial No. 317000001 and Up Operator's Manual Safety Note: Determine the left and right sides of the machine from the normal operating position. Safety and Instructional Decals Safety decals and instructions are easily visible to the operator and are located near any area of potential danger. Replace any decal that is damaged or missing. decal112-7890 112-7890 1.
Procedure 3 4 5 6 7 Description Use Qty. Regulating valve, cap mount Regulating valve, mount Decal (112-7890) 1 1 1 Install the foam control valve. Foam marker finishing kit (sold separately) 1 Install the foam marker finishing kit and the bracket. Foam tube Cable ties Compression nut (blue) Compression nut (white) Brackets Spacers Set screws Mounting rod Foam-nozzle assemblies 1 8 2 2 4 4 4 2 2 No parts required – Route the foam tubes. Install the foam nozzles.
Multi Pro 1750 Sprayers Clear and Blue Tubes Quantity Right boom foam tubes 5.5 m (18 ft) 1 Left boom foam tubes 4.9 m (16 ft) 1 Foam density control tubes N/A N/A 92 cm (3 ft) 1 Compressor to tank loop-back tube 3 Installing the Foam Control Valve Parts needed for this procedure: Multi Pro 5800 Sprayers 1 Regulating valve, cap mount 1 Regulating valve, mount 1 Decal (112-7890) Clear and Blue Tubes Quantity Clear Tube Only Quantity Right boom foam tubes 4.
3. Remove the blue compression nut from the fitting on the tank cap connected to the blue filter tube inside the tank (Figure 1). 4. Install the cap-mounted regulating valve and gasket onto the fitting of the tank cap and position the valve as shown in Figure 1. 6. Installing the Tank Loop-Back Tubing at the Compressor Multi-Pro 1750 Series and WM (Workman) Turf Sprayer Systems Installing the Tank Loop-Back Tubing at the Tank 1. Multi-Pro 1750 Series and WM (Workman) Turf Sprayer Systems 1.
and tighten the blue compression nut by hand (Figure 3). Connecting the Loop-Back Tube and Foam Density Tubes at the Tank and Compressor Multi-Pro 5800 Series Sprayers 1. Remove the white compression nut (Figure 4) fitting at the cap for the tank, and assemble it onto the clear tube 92 cm (3 ft). g206595 Figure 3 Multi Pro WM sprayer shown; Multi Pro 1750 sprayer is similar 1. Toward the compressor 2. Clear tube—compressor to tank loop-back tube 92 cm (3 ft) 3. White compression nut—cap 5.
Routing the Foam-Density-Control Tubes Multi-Pro 5800 Series Sprayers 1. Route the foam density tubes 4.9 m (16 ft) forward from the tank and compressor bracket (located below the chemical tank and behind the fuel tank) along the frame channel of the machine, and toward the area under the seat box (Figure 6). g196403 Figure 5 1. Compression nut (blue—compressor fitting) 4. Clear tube—92 cm (3 ft) 2. Blue tube—foam density tubes 4.9 m (16 ft) 5. Compression nut (white—compressor fitting) 3.
Installing the Foam Density Tubes and the Foam Control Valve Note: The console opening is underneath the valve mount. Multi Pro 5000 Series Sprayers 1. Loosen and remove the compression nuts from the valve body (Figure 10). Note: Retain and set aside the compression nuts. g206083 Figure 8 g206568 3. Valve mount 1. Console opening (underneath the valve mount) Figure 10 2. Tube pair 14.9 m (16 ft) 1. White tube 4. Valve body 2. Compression nut 5. Valve mount 3. Jam nut 6.
4 Installing the Foam Marker Finishing Kit and the Bracket Parts needed for this procedure: 1 Foam marker finishing kit (sold separately) See the installation instructions that came with the foam marker finishing kit. g206499 Figure 11 Multi Pro 5800 model year 2015 and earlier 1. Valve 2. Valve mount 5 3. Decal 112-7890 Routing the Foam Tubes Parts needed for this procedure: 1 Foam tube 8 Cable ties Routing the Foam Tubes to the Booms 1. Install the foam tubes to the booms.
g007655 Figure 15 1. Cable ties D. g197029 Figure 13 Multi-Pro 5000 Series shown 1. Foam tube on the right boom Important: The foam tubes will be pinched when the booms are in the “X” transport position if they are installed on the wrong side. 2. Cable ties 2. B. Repeat the process for the left boom, but route the tube along the front side of the upper support pole. Align the end of the tube with the end of the upper support pole.
6 Installing the Foam Nozzles Parts needed for this procedure: g197028 Figure 17 Multi-Pro 5800 Sprayer 1. Cable ties 2 Compression nut (blue) 2 Compression nut (white) 4 Brackets 4 Spacers 4 Set screws 2 Mounting rod 2 Foam-nozzle assemblies 2. Tube Assembling the Compression Nuts 1. Assemble the blue compression nut onto the blue (fluid) tube (Figure 19). g196925 g196997 Figure 19 Figure 18 Multi-Pro WM Sprayer 1. Cable ties 3. 1. Blue tube 2. Blue compression nut 3. Clear tube 4.
g007666 Figure 20 1. Upper boom tube 3. Spacer (note orientation) 5. Clamp screw 7. Set screw 2. Lower half of the bracket clamp 4. Lower half of the bracket clamp 6. Spacer nut 8. Mounting rod 4. Install the second bracket assembly 7 to 10 cm (3 to 4 inches) inboard from the first bracket. 5. Install a set screw in the top hole of each spacer. 6. Install the mounting rod, with the spline end outward, into the holes in the spacers.
Installing the Foam Nozzles 1. 7 Locate the foam nozzles in loose parts and install a nozzle to the mounting rod as shown (Figure 21). Connecting the Boom Tubes at the Compressor No Parts Required Procedure 1. Route the foam tubes for the right boom as shown in Figure 22. g196495 Figure 22 g007667 Figure 21 1. Spline-end mandrel 3. Blue tube and blue compression nut 2. Foam nozzle 4. Clear tube and white compression nut 1. Blue tubes 2. Liquid fitting (left boom) 6. Electrical connector 7.
6. Operation Insert the blue tube into the liquid fitting at the side compressor plate (Figure 22). Using the Controls Right boom switch—This switch activates the compressor, generating a flow of water and air to the right boom section. Left boom switch—This switch activates the compressor, generating a flow of water and air to the left boom section. Note: You can drop the foam simultaneously from both boom sections.
Maintenance Winterizing g207605 1. Relieve the pressure within the tank by pulling the release valve on the tank. 2. Disconnect the air and liquid tubing from the tank cap. 3. Connect the air and water tubing together with the supplied tubing coupler. 4. Turn on the foam marker for 5 minutes on each side. Figure 23 1. 1/4 turn open 6. 7. Note: This removes the solution from the solenoids and prevents damage from freezing.
Storage 1. Move the vehicle onto a level surface, set the parking brake, stop the pump, shut off the engine, and remove the key. 2. Relieve pressure within tank by opening the tank fill cap, install the tank fill cap, and hand tighten it. 3. Disconnect the air and liquid tubing from the tank. Note: Replace air and liquid tubing together with the supplied tubing coupler. 4. Disassemble the foam nozzles and replace the foam sponges. 5.