Software Guide
Table Of Contents

Note:Thenumbershowninthebox,locatedinthe
upperrightcornerofthescreen,indicatestheactive
sub-areawhereareaandvolumeinformationare
beingcollected.
InfoCenterAdvisories
Operatoradvisoriesautomaticallydisplayonthe
InfoCenterscreenwhenamachinefunctionrequires
additionalaction.Forexample,ifyouattemptto
starttheenginewhilepressingthetractionpedal,an
advisorydisplays,indicatingthatthetractionpedal
mustbeintheNEUTRALposition.
Foreachadvisorythatoccurs,thefaultindicator
ashes,andanadvisorycode(number),anadvisory
description,andanadvisoryqualierappearsonthe
screenasshowninFigure24.
Advisorydescriptionsandqualiersappear
asInfoCentericons.RefertoInfoCenterIcon
Descriptions(page3)foradescriptionofeachicon.
Note:Anadvisoryqualierexplainstheconditions
thattriggeredtheadvisoryandprovidesinstructions
oneliminatingtheadvisory.
g202867
Figure24
1.Faultindicator3.Advisorydescription
2.Advisoryqualier
4.Advisorycode
Note:Advisoriesdonotlogintothefaultlog.
Note:Youcanclearanadvisoryfromthedisplay
screenbypressinganyoftheInfoCenterkeys.
RefertothefollowingtablefortheInfoCenter
advisories:
Advisories
AdvisoryCode
Description
200
StartPrevented—Pumpswitchactive
201
StartPrevented—NotinNEUTRAL
202
StartPrevented—Outofseat
Advisories(cont'd.)
AdvisoryCode
Description
203
StartPrevented—Throttlepedalisnothome
204
StartPrevented—Starterengagetimeout
205Parkingbrakeisengaged
206
PumpStartPrevented—Boomactive
207
PumpStartPrevented—Enginerpmhigh
208
Throttle/SpeedLockPrevented—Pumpis
notactive
209ThrottleLockPrevented—Parkingbrakeis
notengaged
210
SpeedLockPrevented—Operatornotin
seatorparkingbrakeinengaged
211
Throttle/SpeedLockPrevented—Clutchor
servicebrakeisengaged
212Tanklowvolumealert
213
RinsepumpON
220Flowsensorcalibration
221Flowsensorcalibration—Fillwaterintank
andentervolumelled
222Flowsensorcalibration—Turnonthepump
223
Flowsensorcalibration—Turnonallofthe
booms
224
Flowsensorcalibration—Calibration
commenced
225
Flowsensorcalibration—Calibration
complete
226Flowsensorcalibration—Exitingcalibration
mode
231
Speedsensorcalibration
232
Speedsensorcalibration—Fillthefresh
watertank,pressnext
233
Speedsensorcalibration—Fillthesprayer
halffullwithwater,pressnext
234
Speedsensorcalibration—Enterthe
calibrationdistance,pressnext
235
Speedsensorcalibration—Markanddrive
theentereddistancewithsprayersections
off
236
Speedsensorcalibration—Speedsensor
calibrationinprogress
237
Speedsensorcalibration—Speedsensor
calibrationcomplete
238
Speedsensorcalibration—Turnoffthe
booms
241
Calibrationoutofbounds,usingdefault
13










