Service Manual

GeneralInformation
OperatorsManual
TheOperatorsManualprovidesinformationregardingtheoperation,general
maintenanceandmaintenanceintervalsforyourGroundsmastermachine.Refer
tothatpublicationforadditionalinformationwhenservicingthemachine.
CheckHydraulicFluid
1
2
g274850
Figure31
1.Hydraulicreservoir2.Reservoircap
TheGroundsmasterhydraulicsystemisdesignedtooperateonanti−wear
hydraulicuid.Thehydraulicreservoirlocatedbeneaththeoperatorseatholds
approximately29.3liters(7.75U.S.gallons)ofhydraulicuid.Checklevelof
hydraulicuiddaily.SeeOperatorsManualforuidlevelcheckingprocedure
andoilrecommendations.
RelievingHydraulicSystemPressure
Beforedisconnectingorperforminganyworkonthehydraulicsystem,all
pressureinthehydraulicsystemmustberelieved.Parkmachineonalevel
surface,makesurethatPTOswitchisOFF ,lowercuttingdecksfully,stopengine
andengageparkingbrake.Waitforallmovingpartstocometoacompletestop.
Systempressureinliftcircuitisrelievedwhenthecuttingdecksarefullylowered.
SystempressureinmowcircuitisrelievedwhenthePTOswitchisdisengaged.
Torelievehydraulicpressureintractioncircuit,turnignitionswitchtoON(engine
notrunning)andmovetractionpedaltobothforwardandreversedirections.
TurnignitionswitchtoOFFafterrelievingtractioncircuitpressure.
Torelievehydraulicpressureinsteeringcircuit,rotatesteeringwheelinboth
directions.
Afterallhydraulicsystempressureshavebeenrelieved,removekeyfrom
ignitionswitch.
Groundsmaster
®
4000-D&4010-D
Page5–3
HydraulicSystem:GeneralInformation
13202SLRevE