Service Manual
HydraulicSolenoidValveCoils
FRONT
RIGHT
2
3
1
4
g276029
Figure221
1.FrontPTOmanifold3.LHPTOmanifold
2.RHPTOmanifold4.Combinationmanifold
Severalhydraulicsolenoidvalvecoilsareusedonthehydrauliccontrolmanifolds
ofGroundsmaster4000−Dand4010−Dmachines.WhenenergizedbytheTEC
controller,thesecoilsprovidehydrauliccircuitcontrol.
Solenoidvalvecoilswithtwo(2)differentresistancespecicationsareusedon
the4000−Dand4010−D.Thecorrectresistanceofacoilcanbeidentiedby
measuringtheheightanddiameterofthecoil(Figure222).Resistancetestingof
thecoilscanbedonewiththecoilremainingonthehydraulicvalve.
Note:Toassistintroubleshooting,identicalsolenoidcoilscanbeexchanged.If
theproblemfollowstheexchangedcoil,aproblemwiththecoillikelyexists.If
theproblemremainsunchanged,somethingotherthanthesolenoidcoilisthe
problemsource(e.g.switch,circuitwiring,hydraulicproblem).Refertoyour
PartsCatalogtodetermineifsolenoidcoilsareidentical.
Groundsmaster
®
4000-D&4010-D
Page6–65
ElectricalSystem:ComponentTesting
13202SLRevE