Operator's Manual

HydraulicSystem
Maintenance
ReplacingtheHydraulicFilter
ServiceInterval:Aftertherst8hours
Every400hours
Important:Donotsubstituteanautomotiveoillteror
severehydraulicsystemdamagemayresult.
Changethehydrauliclteraftertherst8operatinghours
andthenevery400operatinghoursthereafter.
1.Positiontractionunitonalevelsurface.
2.Raisetheloaderarmsandinstallthecylinderlocks,
stoptheengine,andremovethekey.
3.Placeadrainpanunderthelter.
4.Removetheoldlter(
Figure35)andwipethesurface
ofthelteradaptergasketclean.
Figure35
1.Hydrauliclter
5.Applyathincoathydraulicuidtotherubbergasket
onthereplacementlter(Figure35).
6.Installthereplacementhydrauliclterontothelter
adapter(Figure35).Tightenitclockwiseuntilthe
rubbergasketcontactsthelteradapter,thentighten
thelteranadditional1/2turn.
7.Cleanupanyspilleduid.
8.Starttheengineandletitrunforabouttwominutesto
purgeairfromthesystem.
9.Stoptheengineandcheckforleaks.
WARNING
Hydraulicuidescapingunderpressurecan
penetrateskinandcauseinjury.Fluidinjected
intotheskinmustbesurgicallyremoved
withinafewhoursbyadoctorfamiliarwith
thisformofinjuryorgangrenemayresult.
Keepyourbodyandhandsawayfrom
pinholeleaksornozzlesthatejecthigh
pressurehydraulicuid.
Usecardboardorpapertondhydraulic
leaks,neveruseyourhands.
10.Checktheuidlevelinthehydraulictank(referto
CheckingtheHydraulicFluidLevel(page16))andadd
uidtoraisetheleveltomarkondipstick.Donotover
llthetank.
11.Removeandstorethecylinderlocksandlowerthe
loaderarms.
ChangingtheHydraulicFluid
ServiceInterval:Yearly
HydraulicFluidSpecication:
Useonlyoneofthefollowinguidsinthehydraulicsystem:
ToroPremiumTransmission/HydraulicTractor
Fluid(refertoyourAuthorizedToroDealerformore
information)
ToroPremiumAllSeasonHydraulicFluid(referto
yourAuthorizedToroDealerformoreinformation)
IfneitheroftheaboveTorouidsareavailable,
youmayuseanotherUniversalTractorHydraulic
Fluid(UTHF),buttheymustbeonlyconventional,
petrolium-basedproducts.Thespecicationsmustfall
withinthelistedrangeforallofthefollowingmaterial
propertiesandtheuidshouldmeetthelistedindustry
standards.Checkwithyouroilsuppliertodetermineif
theoilmeetsthesespecications.
Note:Torowillnotassumeresponsibilityfordamage
causedbyimpropersubstitutions,souseonlyproducts
fromreputablemanufacturerswhowillstandbehindtheir
recommendations.
MaterialProperties
cStat40degreesC:55to62 Viscosity,ASTMD445
cStat100degreesC:9.1to
9.8
Viscosityindex,ASTMD2270
140to152
PourPoint,ASTMD97-35to-46degreesF(-37to
-43degreesC)