Installation Instructions

Figure18
Wiringharnesswithcableties
7.RoutetheconnectorsmarkedSetupValveuptothe
9-sectionvalveblocktothetopsolenoidmarkedSetup
Valve(Figure18).
8.Disconnecttheconnectorfromthetopsolenoidvalve
andplugitintothematingconnectoronthenew
harness.
9.Plugtheotherconnectorintothevalveyoupreviously
disconnected.
10.Locatetheroundconnectorontheexistingharness
thatwaspreviouslyconnectedtotheproximitysensor
(Figure18).
11.Unscrewtheconnector,removethecabletiessecuring
thiswire,andattachtheexistingconnectortothe
connectoronthenewharness(Figure18).
12.Routetheremainderofthenewharnessalongthe
existingharnessunderthethrustframe(Figure15).
13.RoutethewireswiththeRotarySensorconnector
alongthethrustframewiththeexistingharnesstoward
therearofthemachineandcontinuetoroutethe
harnessalongthehydrauliclinesasshowninFigure19.
Figure19
Wiringharnesswithcableties
14.Connecttheconnectorstotheproximitysensorand
therotarysensor(Figure19).
Note:Securethewiringharnesstothemachineas
showninFigure20.
Figure20
15.Installthelatestversionofsoftwareintothemachine
andcompletethetestsdescribedinthatsoftware
update.
4
RemovingtheRotaryPump
SupplyandDrainOrices
Partsneededforthisprocedure:
1
Gasket
RemovingtheRotaryPumpSupplyand
DrainOrices
Important:Allowtheenginetocool.
1.Placeaoilpanunderthemachinetocatchoilfrom
therotarypump.
2.Removeandplugthecasedrainlinefromtherotary
pumpandcapoffthecasedrainttingtominimize
hydraulicuidloss.
9