Operator's Manual

Important:ToroPremiumSynthetic
BiodegradableHydraulicFluidistheonly
syntheticbiodegradableuidapprovedbyToro.
Thisuidiscompatiblewiththeelastomersused
inTorohydraulicsystemsandissuitablefora
wide-rangeoftemperatureconditions.Thisuidis
compatiblewithconventionalmineraloils,butfor
maximumbiodegradabilityandperformance,the
hydraulicsystemshouldbethoroughlyushedof
conventionaluid.Theoilisavailablein19L(5
USgallons)pailsor208L(55USgallons)from
yourauthorizedTorodistributor.
HydraulicFluidCapacity
30L(8USgallons);refertoHydraulicFluid
Specications(page58)
ChangingtheHydraulic
Fluid
ServiceInterval:Every2,000hours—Ifyou
areusingtherecommended
hydraulicuid,changethe
hydraulicuid.
Every800hours—Ifyouarenotusingthe
recommendedhydraulicuidorhaveever
lledthereservoirwithanalternativeuid,
changethehydraulicuid.
Iftheuidbecomescontaminated,contactyour
authorizedTorodistributortoushthesystem.
Contaminateduidlooksmilkyorblackwhen
comparedtocleanuid.
1.Parkthemachineonalevelsurface,lowerthe
cuttingunits,shutofftheengine,engagethe
parkingbrake,andremovethekey.
2.Raisethehood.
3.Placealargedrainpanunderthettingsecured
tothebottomofthehydraulic-uidreservoir
(Figure99).
g004139
Figure99
1.Hose
4.Disconnectthehosefromthebottomofthe
ttingandletthehydraulicuidowintothe
drainpan.
5.Installthehosewhenhydraulicuidstops
draining.
6.Fillthereservoirwithhydraulicuid;referto
HydraulicFluidSpecications(page58)and
HydraulicFluidCapacity(page59).
Important:Useonlyhydraulicuids
specied.Otheruidscoulddamagethe
system.
7.Installthereservoircap.
8.Starttheengineanduseallofthehydraulic
controlstodistributehydraulicuidthroughout
thesystem.
9.Checkforleaks.
10.Shutofftheengine.
11.Checkthelevelofthehydraulicuidandadd
enoughtoraisetheleveltotheFULLmarkon
thedipstick.
Important:Donotoverllthereservoir.
59