4. Position new flange gasket onto tank aligning
mounting holes (Fig. 7). Holes are not symmetrical so
make sure gasket is properly positioned.
5. Insert leak detector into tank opening while aligning
housing mounting with holes in gasket (Fig. 7).
1
2
3
4
Figure 7
1. Flange gasket
2. Tank flange
3. Leak detector
4. Electric solenoid valve
6. Secure leak detector housing and gasket to tank with
(6) socket head capscrews (Fig. 7). Torque screws to
100–125 in–lb.
7. Re–install fender and control console, if previously
removed.
8. Remove front capscrew and locknut securing fuse
block bracket to side of control console (Fig. 8).
9. Mount alarm bracket to fuse block bracket with
capscrew and locknut previously removed. Position
bracket and alarm as shown in figure 8.
1
2
3
Figure 8
1. Fuse block bracket
2. Alarm bracket
3. Alarm
Note: If traction unit is equipped with a plastic operator’s
console, mount the alarm bracket as follows:
• Using the dimensions shown in figure 9, locate,
mark and drill a 9/32” dia. hole in operator’s side
of console.
6”
3”
9/32” dia
Figure 9
10. Mount alarm bracket to console with a 1/4–20 x 3/4”
lg. capscrew, (2) 1/4” washers and locknut supplied in
kit. Position bracket, fasteners and alarm as shown in
figure 10.
Important Apply RTV silicone on the bracket surface
that will contact inside of console