Installation Instructions
2
1
2
3
4
Figure 4
1. Flange gasket
2. Tank flange
3. Leak detector
4. Electric solenoid valve
8. Locate and remove the cap plug from the back side of
the hydraulic tank cover (Fig. 5).
2
1
Figure 5
1. Hydraulic tank cover 2. Cap plug
9. From inside the cover, insert the alarm into the hole
and secure with the plastic nut. Alarm terminals must
be positioned to the inside of the cover.
10. Locate the leak detector harness from traction unit’s
main wire harness. Plug harness connector into
connector on leak detector harness.
11. Locate (2) spade terminal wires on leak detector
harness. Plug red wire onto (+) positive terminal of
leak detector alarm and other wire onto (–) negative
terminal. Do not switch wire connections.
Installation on Reelmaster 5000/6000
Series
1. Park machine on a level surface, stop the engine and
engage the parking brake.
Important On Reelmaster traction unit’s with serial
numbers prior to 69999, an update to the software is
required to accommodate the TurfDefender. Contact your
authorized Toro Distributor for assistance.
Note: Before the leak detector kit can be installed on most
Reelmaster traction units with serial numbers prior to
59999, the hydraulic tank must be replaced with
Hydraulic Tank Kit, Model 03522. Contact your
authorized Toro Distributor for assistance.
2. Open control panel cover. Thru hole in right fender,
thoroughly clean top of hydraulic tank around tank
cover (Fig. 6).
1
2
3
4
5
Figure 6
1. Control console
2. Right fender
3. Tank cover
4. Gasket
5. Hydraulic tank
Note: To simplify cleaning of tank and installation of kit,
remove fasteners securing control console and fender to
machine and move off tank.
3. Remove (6) flange head screws (Fig. 6) securing tank
cover and gasket to tank and remove components from
tank. Discard components.