User Manual

TopSeed Technology Corp.
SPECIFICATION FOR
RF Optical Mouse
PAGE: 15/15
DATE: 2002/08/01
9. Environmental Tests
NOTE: When using RF products, keep away from hi-frog electric products.
APPD.
CHKD.
DSGD.
SYMB.
PAGE
DATE
APPD.
SHKD.
OSGD.
SPEC. NO.
MSBG0002-902
RF Optical Mouse
FSK (912MHZ)
ITEM SPECIFICATION
9.1
Heat load test
Measure initial value at standard testing conditions.
Leave samples in 602C for 965 hours, and in
standard
testing conditions for 2 hours, then take measurements
within 1 hour.
9.2
Humidity load
test
Leave samples in 405C for 242 hours, and in standard
testing conditions for 2 hours, then take measurements.
Leave samples in 405C, 90~95%RH, for 96
5 hours, and
in standard testing conditions for 2 hours, then
take
measurements within 1 hour.
9.3
Cold test
Measure initial value at standard testing conditions.
Leave samples in -152C for 96
5 hours, and in Standard
testing conditions for 2 hours, then take Measurements within
1 hour.
9.4
Vibration test
Vibration test fixture is used to vibrate the tuner with a total
amplitude 1mm and frequency ranging from 10 to 55Hz, once
per minute onsecutively, for
40 minutes in each of three directions. X. Y and Z
9.5
HEAT CYCLE
TEST
Measure initial value at standard testing conditions.
1. Conditions
2.Test
cycle:
10 cycles