User Manual
TopSeed Technology Corp.
SPECIFICATION FOR
Remote Pointer-BD type
PAGE: 15/15
DATE: 2002/7/25
9. Environmental Tests
ITEM SPECIFICATION
9.1
Heat load test
Measure initial value at standard testing conditions.
Leave samples in 60
±
2
。
C for 96
±
5 hours, and in standard testing
conditions for 2 hours, then take measurements within 1 hour.
9.2
Humidity load
test
Leave samples in 405C for 242 hours, and in standard
testing conditions for 2 hours, then take measurements.
Leave samples in 40
±
5
。
C, 90~95%RH, for 96
±
5 hours, and in
standard testing conditions for 2 hours, then
take measurements
within 1 hour.
9.3
Cold test
Measure initial value at standard testing conditions.
Leave samples in -15±2。C for 96±
5 hours, and in Standard testing
conditions for 2 hours, then take Measurements within 1 hour.
9.4
Vibration test
Vibration test fixture is used to vibrate the tuner with a total
amplitude 1mm and frequency ranging from 10 to 55Hz, once
per minute onsecutively, for
40 minutes in each of three directions. X. Y and Z
9.5
HEAT CYCLE
TEST
Measure initial value at standard testing conditions.
1. Conditions
2.Test cycle: 10 cycles
NOTE: When using RF products, keep away from hi-frog electric products.
APPD.
CHKD.
DSGD.
SYMB.
PAGE
DATE
APPD.
SHKD.
OSGD.
SPEC. NO.
RCBD0003-903
Remote Pointer
FSK (912MHZ)