6. Electrical Characteristics:
6.1 GENERAL SPECIFICATION
6.1.1 OPERATING CONDITIONS
Temperature 0 ~ 40
Relative humidity 10 ~ 85% RH (non-condensing)
6.1.2 STORAGE CONDITIONS
Temperature -10 ~60
Relative humidity 5 ~ 90% RH (non-condensing)
Test and Measurement conditions
6.2 Operational Range
Parameter Min Max Unit
Supply Voltage 2.4 3.3 V
Frequency (Europe) 433.1 434.675 MHZ
Ambient temperature -10 60
6.3 Electrostatic Discharge (ESD) Sensitivity
Direct discharge:
Test Voltage: Not less than 8 KV for Air discharge
Not less than 4 KV for Contact discharge
Indirect discharge:
Test Voltage: Not less than 4 KV for HCP
Not less than 4 KV for VCP