User Guide
4
5
6
WARRANTY INFORMATION
TROUBLESHOOTING
This device is warranted to be free of material and workmanship defects for 5 years from
the date of purchase. Original receipt or proof of purchase from an authorized retailer must
be presented upon warranty claim. ALL claims must be verified and approved by Top
G
reener, Inc. Warranties from other Top Greener products may vary. This warranty is
nontransferable and does not cover normal wear and tear or any malfunction, failure, or
defect resulting from misuse, abuse, neglect, alteration, modification, or improper
installation. To the fullest extent permitted by the applicable state law, Top Greener shall
not be liable to the purchaser or end user customer of Top Greener products for direct,
indirect, incidental, or consequential damages even if Top Greener has been advised of the
possibility of such damages. Top Greener’ total liability under this or any other warranty,
express or implied, is limited to repair, replacement or refund. Repair, replacement or
refund are the sole and exclusive remedies for breach of warranty or any other legal theory.
© 2016 TOPGREENER Inc.
CA, U.S.A.
WWW.TOPGREENER.COM
0207160027
1.
Make sure the sensor has completed 3 minutes warm up time.
2.
Keep close to the sensor to make sure you are in the detection range.
3.
Check the LED indicator on the sensor to see whether it flashes when
motion is detected. If LED indicator flashes when motion detected, please go to
Step 4. If LED indicator stays off when there is motion, please go to Step 5.
4.
Check the mode of the sensor and make sure it is on OCC (occupancy).
5.
Check the wiring connection to make sure a secure ground has been
connected.
NOTE: There is a 3 minute warm-up time at initial power-up.
Allow the sensor to complete the warm-up before operation
or making adjustments. The load may turn on/off several
times during the warm-up.
The Load doesn't turn on when motion is detected:
1. Make sure there is no motion detected by the sensor.
2. Check for possible significant heat sources emitting within six feet (two
meters) such as high wattage light bulbs, portable heaters or HAVC vents
which may be triggering the sensor.
3. If the sensor is installed in a small room, turn the Range dial to a lower
setting to avoid false or unwanted detection from a open window or door.
4. Choose to use VAC mode instead of OCC mode to avoid false triggering.
OCCupancy position: The Load will automatically turn ON when motion is
detected and automatically turn OFF when the selected time delay has
expired.
VACancy position: The Load will turn ON ONLY when the push button is
used and automatically turns OFF when the selected time delay has expired.
If the time delay has expired and the Load turns OFF
, the Load will turn ON
again automatically if motion is detected within 30 seconds.
Figure 5
INSTALLATION INSTRUCTIONS
The Load does not turn Off:
1.
Check the time delay option. The time delay constantly restarts its
countdown after the last motion detected. Turn the Time Delay Knob to 15s
(Test Mode) and make sure there is no motion (Tape may be used to cover
the fresnel lens while testing.)
2.
Check for possible significant heat sources emitting within six feet (two
meters) such as high wattage light bulbs, portable heaters or HAVC vents
which may be triggering the sensor.
3.
Check the wiring. Make sure no connection between Hot wire and Load
wire.
The Load turns on when not desired: