User Guide

Position
1
2
INSTALLATION INSTRUCTIONS
SPECIFICATIONS
DESCRIPTION
3
WARNING
Turn the POWER OFF at the circuit breaker before installing the
sensor
Read and understand these instructions before installing. This device
is intended for installation in accordance with the National Electric Code
and local regulations. It is recommended that a qualified electrician
performs this installation. Make sure to turn off the circuit breaker or
fuse(s) and make sure power is off before wiring the device.
Use copper wires only.
WIRING DIRECTIONS
As illustrated in Figure 1, The TDOS5-J has a 180° detection range with a
maximum distance of 40’ detection in front of the sensor and 20' on the sides.
For maximum results, the sensor must be properly installed between the
height of 4’ to 5’ and away from obstructions such as walls, furniture and
transparent barriers like Low-E glass.
The TDOS5-J uses advanced passive infrared sensor to detect heat emitted
from motion. The sensor switch can turn on a load and keep it on as long as it
detects motion. The sensor will automatically shut off the load at the end of
the selected time delay. The selected time delay begins to count down after
the last motion was detected. The sensor is customizable with dials that can
adjust Time Delay, detection Range, ambient Light Level, and a switch to
change between Occupancy/ Vacancy modes.
1. Connect one BLACK lead to the Hot wire.
2. Connect the other BLACK lead to the Load wire.
3. Connect GREEN lead to the Ground wire.
ADJUSTMENT
TDOS5-J
OCCUPANCY / VACANCY (2-IN-1)
SENSOR SWITCH
Incandescent .......................................................................… 800W
Time Delay..........................................................…… 15Sec to 30Mins
Light Level.................................................................... 30 Lux--Daylight
Fluorescent/Ballast......................800VA@120VAC /1600VA@277VAC
Operation Temperature.................................................. 32 °F--131 °F
Voltage .................................................................... 120/277VAC,60Hz
Motor ...................................................................................…… 1/4Hp
COVERAGE
Figure 1
Max. 20'
on the sides
Max. 40'
from front
Installation
Height: 4' - 5'
Detection Range
Wiring Diagram
Hot/Load
Black
Ground
Green
Load/Hot
Black
The control panel cover is also the push button on the switch. Remove the
push-button cover plate by prying from the bottom of the push-button and
pulling outward.
Time dial (Figure 4.a)
This dial adjusts the time delay. Default position: 15 Seconds (Test mode)
Adjustable: from 15 Seconds to 30 Minutes (clockwise)
Range dial (Figure 4.b)
This dial adjusts the detection range. Default position: Center at 65%
Adjustable: 30% (Position 1) to 100% (Position 4).
Note: Use a higher setting for a larger coverage area.
Figure 2
Figure 3
Switch Type......................................................................... Single Pole
Note: The BLACK wires on the sensor are interchangeable between
HOT and LOAD.
Figure 4
Figure 4.a
Figure 4.b
OPERATION
Mode Switch: OFF/ Occupancy/ Vacancy
OCC
Mode
OFF
VAC
Description
Occupancy Mode:
Automatic On, automatic Off
after set time delay.
Left
Center
Right
Vacancy Mode: Manual On only,
automatic Off after set time delay.
Push-Button Function
Manually toggles
Manually toggles
On / Off the load.
On / Off the load.
Circuit is permanently opened.
( switched off)
Manual ON/OFF Button: In occupancy and vacancy mode, the push
button can be used to manually turn ON/OFF the load. There is a 5
seconds reset delay after each push of the button to trigger the ON/OFF.
None