TROUBLESHOOTING
TOPGREENER offers a 2 year warranty on this product to be free of defects in material and
workmanship. This warranty is voided if this product is installed improperly or in an improper
environment, overloaded, misused or altered in any manner. TOPGRENER is not liable for
consequential damages arising out of, or in connection with the use or performance of this
product or other indirect damages with respect to loss of property, revenue or profit or cost
of removal, installation or reinstallation.
© 2016 TOPGREENER Inc.
CA, U.S.A.
WWW.TOPGREENER.COM
0207160028
OPERATION
TSOS5 Band Switch Operation
AUTO
OFF
ON
Mode
Position
Left
Center
Right
Load stays On always.
Description
Circuit is permanently opened.
(switched off)
Occupancy Mode:
Automatic On when occupancy is detected.
Automatic Off after the set time delay.
(switched on)
Band switch on the TSOS5
Figure 5
The Load flashes in 'AUTO' mode:
Check the wire connection. Make sure the white wire on the sensor is connected to
the neutral wire in the junction box. Do not connect the white wire to any other wire
besides the neutral.
The Load does not turn on when motion is detected:
1. Keep close to the sensor to make sure you are in the detection range.
2. Check the LED indicator on the sensor to see whether it flashes when motion is
detected. If LED indicator flashes when motion detected, please go to Step 3. If
LED indicator stays off when there is motion, please go to Step 4.
3. Make sure the sensor is in 'AUTO' mode.
4. Check the wiring connection to make sure neutral wire has been connected and
make sure Hot and Load wires are not reversely connecte.
The Load does not turn Off:
1.
Make sure the sensor is in 'AUTO' mode. (Light is always on when it is switched to
'ON')
2.
Check the time delay option. The time delay constantly restarts its countdown after
the last motion detected. Turn the Time Delay Knob to 15s (Test Mode) and make sure
there is no motion (Tape may be used to cover the fresnel lens while testing.)
3.
Check for possible significant heat sources emitting within six feet (two meters)
such as high wattage light bulbs, portable heaters or HAVC vents which may be
triggering the sensor.
4.
Check the wiring. Make sure no connection between Hot wire and Load.
1. Make sure there is no motion detected by the sensor.
2. Check for possible significant heat sources emitting within six feet (two
meters) such as high wattage light bulbs, portable heaters or HAVC
vents which may be triggering the sensor.
3. If the sensor is installed in a small room, turn the Range dial to a lower
setting to avoid false or unwanted detection from a open window or
door.
The Load turns on when not desired: