User Manual
1
2
INSTALLATION INSTRUCTIONS
DESCRIPTION
3
WARNING
Turn the POWER OFF at the circuit breaker before installing the
sensor
Read and understand these instructions before installing. This device
is intended for installation in accordance with the National Electric Code
and local regulations. It is recommended that a qualified electrician
perform
s this installation. Make sure to turn off the circuit breaker or
fuse(s) and make sure power is off before wiring the device.
Use copper wires only.
WIRING DIRECTIONS
As illustrated in Figure 1, The TSOS5 has a 180° detection range with a
maximum distance of 30’ detection in front of the sensor and 15' on the
sides. For maximum results, the sensor must be properly installed between
the height of 4’ to 5’ and away from obstructions such as walls, furniture and
transparent barriers like Low-E glass.
The TSOS5 uses advanced passive infrared sensor to detect heat emitted
motion. The sensor switch can turn on a load and keep it on as long as it
detects motion. The sensor will automatically shut off the load at the end of the
selected time delay. The countdown of the selected time delay starts after the
last motion detected. The sensor is customizable with dials that can adjust
Time Delay, detection Range, and ambient Light Level.
1. Connect RED wire from sensor to the
LOAD wire.
2.
3.
4.
Connect BLACK
wire from sensor to the HOT wire.
Connect GREEN wire from sensor to the GROUND wire.
Connect WHITE wire from sensor to the NEUTRAL wire.
ADJUSTMENT
TSOS5
OCCUPANCY SENSOR
SWITCH
Incandescent .......................................................................… 500W
Time Delay..........................................................…… 15Sec to 30Mins
Light Level.................................................................... 30 Lux--Daylight
Fluorescent..................................................................................500VA
Operation Temperature.................................................... 32°F--131 °F
Voltage .......................................................................... 120VAC,60Hz
Motor ...................................................................................…… 1/8Hp
COVERAGE
Figure 1
Max. 15'
on the sides
Max. 30'
from front
Installation
Height: 4' - 5'
Detection Range
The control panel is located behind the cover plate directly below the PIR
sensor. Pull from top corners of cover to uncover control dials (Figure 3).
LED Indicator
Mounting Yoke
Fresnel Lens
Figure 4
Figure 3
Neutral
White
Hot
Black
Ground
Green
Load
Red
Neutral
White
TSOS5
Illustrated in Figure 4, the control dials are used to adjust the following:
Time dial
This dial adjusts the time delay. Default position: 15 Seconds (Test mode)
Adjustable: from 15 Seconds to 30 Minutes (clockwise)
Range dial
This dial adjusts the detection range. Default position: Center at 65%
Adjustable: 30% (Position 1) to 100% (Position 4).
Note: Use the greater setting for larger coverage area.
Light dial
The sensor may be adjusted to operate at the desired level of ambient light.
• To do so, turn the dial to point the arrow toward the “-”sign for sensor to
detect motion and operate during low light or no light. Point the arrow
toward the “+”sign for sensor to operate when there’s more light in the
area or even during daylight.
TSOS5
SPECIFICATIONS
Figure 2
TSOS5
Switch Type........................................................................ Single Pole
Note: The white wire MUST be connected to the neutral wire in the junction box.
Please do not connect the white wire to any other wire besides the neutral.