INSTRUCTION MANUAL ROTATING LASER RL-SV2S 31365 90030
FOREWORD Thank you for selecting the TOPCON instrument. • Please read this instruction manual carefully before using this instrument. • Verify that all equipment is included. C “ STANDARD SYSTEM COMPONENTS” (p. iii) • The specifications and general appearance of the instrument are subject to change without prior notice and without obligation by Topcon Corporation and may differ from those appearing in this manual. • Some of the diagrams shown in this manual may be simplified for easier understanding.
HOW TO READ THIS MANUAL XSymbols The following conventions are used in this manual. Indicates precautions and important items which should be read before : G operations. C : Indicates the chapter title to refer to for additional information. $ : Indicates supplementary explanation.
STANDARD SYSTEM COMPONENTS Rechargeable battery type Dry battery type 1) RL-SV2S Instrument .......................................1pc. 2) Remote controller RC-60 (with AA Manganese battery x 2pcs.) .............1pc. 3) Level Sensor LS-80L.......................................1pc. 4) Model-6 Level Sensor Holder .........................1pc. 5) Battery holder DB-74C ....................................1pc. 6) Ni-MH battery pack BT-74Q ............................1set 7) AC/DC converter AD-15 .............
CONTENTS FOREWORD ................................................................................................................................. I HOW TO READ THIS MANUAL................................................................................................... II STANDARD SYSTEM COMPONENTS ...................................................................................... III CONTENTS .............................................................................................................
CONTENTS RL-SV2S (Rechargeable battery type)...................................................................... 20 RC-60........................................................................................................................ 23 LS-80L....................................................................................................................... 23 5.2 How to set remote controller communication channel .................................................. 24 RL-SV2S ...........
CONTENTS 8. 9. 10. 11. 12. 13. vi How to change the rotary head speed ...................................................................... 42 Switching Auto leveling / Manual Mode .................................................................... 43 Setting channel ......................................................................................................... 44 Sleep mode ON/OFF ................................................................................................
1. PRECAUTIONS FOR SAFE OPERATION For the safe use of the product and prevention of injury to operators and other persons as well as prevention of property damage, items which should be observed are indicated by an exclamation point within a triangle used with WARNING and CAUTION statements in this instruction manual. The definitions of the indications are listed below. Be sure you understand them before reading the manual’s main text.
1. PRECAUTIONS FOR SAFE OPERATION General Warning Do not perform disassembly or rebuilding. Fire, electric shock or burns could result. Do not use the unit in areas exposed to high amounts of dust or ash, in areas where there is inadequate ventilation, or near combustible materials. An explosion could occur. When securing the instrument in the carrying case make sure that all catches, including the side catches, are closed.
1. PRECAUTIONS FOR SAFE OPERATION Power Supply Warning Do not short circuit. Heat or ignition could result. Do not use voltage other than the specified power supply voltage. Fire or electrical shock could result. Do not use damaged power cords, plugs or loose outlets. Fire or electric shock could result. Do not use power cords other than those designated. Fire could result. Do not use batteries other than those designated. An explosion could occur, or abnormal heat generated, leading to fire.
1. PRECAUTIONS FOR SAFE OPERATION Do not heat or throw batteries into fire. An explosion could occur, resulting in injury. Do not use the battery or charger for any other equipment or purpose. Fire or burns caused by ignition could result. To prevent shorting of the battery in storage, apply insulating tape or equivalent to the terminals. Otherwise shorting could occur, resulting in fire or burns. Do not use batteries or the battery charger if wet. Resultant shorting could lead to fire or burns.
1. PRECAUTIONS FOR SAFE OPERATION Tripod Caution When mounting the instrument to the tripod, tighten the centering screw securely. Failure to tighten the screw properly could result in the instrument falling off the tripod, causing injury. Tighten securely the leg fixing screws of the tripod on which the instrument is mounted. Failure to tighten the screws could result in the tripod collapsing, causing injury. Do not carry the tripod with the tripod shoes pointed at other persons.
2. PRECAUTIONS Before starting work or operation, be sure to check that the instrument is functioning correctly with normal performance. Vibration and Impact Protection When transporting the instrument, provide protection to minimize risk of severe vibration or impact. Severe vibration or impacts may affect beam accuracy. Protection against abrupt change in temperature Do not leave the instrument under strong sunlight for a long time. It may cause the instrument to malfunction.
2. PRECAUTIONS • The manufacturer, or its representatives, assumes no responsibility for consequential damage, and loss of profits by any disaster, (an earthquake, storms, floods etc.). A fire, accident, or an act of a third party and/or a usage any other usual conditions. • The manufacturer, or its representatives, assumes no responsibility for any damage, and loss of profits due to a change of data, loss of data, an interruption of business etc., caused by using the product or an unusable product.
3. LASER SAFETY INFORMATION The RL-SV2S is classified as a class 3R Laser Product according to IEC Standard Publication 60825-1 Ed.2.0: 2007 and United States Government Code of Federal Regulation FDA CDRH 21CFR Part1040.10 and 1040.11 (Complies with FDA performance standards for laser products except for deviations pursuant to Laser Notice No.50, dated June 24, 2007.) Laser Safety This product projects a visible laser beam during operation.
3. Laser Safety Information Visible laser Laser output: 2.4mW CLASS IIIa LASER PRODUCT VISIBLE LASER BEAM Beam aperture Explanatory Label Each lavel is differed by the market. Warning Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. Do not look directly into the laser beam. Doing so could cause permanent eye damage.
3. Laser Safety Information Do not stare at the laser beam. Doing so could cause permanent eye damage. Never intentionally point the laser beam at another person. The laser beam is injurious to the eyes and skin. Caution Perform checks at start of work and periodic checks and adjustments with the laser beam emitted under normal conditions. When the instrument is not being used, turn off the power. When disposing of the instrument, destroy the battery connector so that the laser beam cannot be emitted.
4. NOMENCLATURE 4.
4. Nomenclature Key 12 Nomenclature Function Enter key End Operation of Data Input and Sends data to the instrument. Menu/Escape key Selects a menu item. Cancels input or escape to previous status. X/Y axis selection key/ Alignment key Horizontal rotation: changes to the grade setting screen for each axis. Vertical rotation: changes to the Alignment Mode.
4.
4. Nomenclature 4.2 Remote controller RC-60 RC-60 Nomenclature Display Menu key/Escape key Arrow keys Enter key X/Y axis selection key/Alignment key/ Up key Strap hole RC-60 Display Display is the same as the RL-SV2S. C“RL-SV2S Display” (p. 13) Battery power display will show the remaining battery level on the RC-60 remote controller.
4. Nomenclature 4.3 Level Sensor LS-80L LS-80L Nomenclature Power switch The power switch turns ON or OFF by pressing. On-Grade precision switch Two on-grade precision options are available, normal precision (±2mm) and high precision (±1mm). By pressing this switch, the precision options are switched alternately. Confirm the precision choice by the indicator. (Normal precision is the default setting each time the sensor is turned on.
4. Nomenclature LS-80L Display Height alert warning of rotating laser*1 A flash and a buzzer sound signifies that the height alert function of the RL-SV2S is High precision mode Normal precision mode Higher than datum position (Buzzer sound:High frequent beep sound) Move the sensor downward. Datum position Rotating laser battery warning*2 (Buzzer sound:Continuous beep sound) Lower than datum position A flash shows that the RL-SV2S power is low.
4.
5. PREPARATION AND FUNCTIONS 5.1 Power Source Connect the battery according to the battery type purchased. RL-SV2S (Dry battery type) • How to install dry cell batteries 1 Remove the DB-74 battery holder by turning battery holder knob to "OPEN" side. 2 Install the new 4xD size dry cell batteries (alkaline) referring to the illustration on the DB-74 battery holder.*1), 2), 3) 3 Install the battery holder. Tighten the battery cover knob to "LOCK" side.
5. Preparation and Functions • How to remove dry cell batteries 1 Remove the DB-74 battery holder by turning battery holder knob to "OPEN" side. 2 Remove the dry cell batteries from the DB-74 battery holder. G *1 Replace all 4 batteries with new ones at the same time. Do not mix used and new batteries, and do not mix different types of batteries together. *2 Use alkaline dry cells. (Dry cells for movement confirmation are packed in shipment.
5. Preparation and Functions RL-SV2S (Rechargeable battery type) • How to install the battery pack ÂÔ·´Ñ 1 Insert the battery pack BT-74Q into the DB-74C battery holder in the direction shown in the diagram on the right. 2 Install the battery holder. Tighten the battery cover knob to "LOCK" side. Ä·´Ã • How to remove the battery pack 1 Remove the DB-74C battery holder by turning battery holder knob to "OPEN" side.
5. Preparation and Functions • For Charging Plug AD-15 1 Plug the AC/DC converter (AD-15) into the DB-74C battery holder or plug the AD-15 into the battery pack BT-74Q. 2 Insert the AD-15 power cord in an outlet. 3 Complete charging by unplugging the plug from the DB-74C battery holder or battery pack BT-74Q after approximately 13 hours. 4 Unplug the AD-15 power cord from the outlet.
5. Preparation and Functions G • Recharging should take place in a room with an ambient temperature range of 10°C to 40°C (50°F to 104°F). • Do not perform charging with others except the AC/DC converter AD-15. • For longer battery life, conform to the suggested charging time to the extent possible. • The battery source will discharge when stored and should be checked before using with instrument. • Be sure to charge stored battery source every 3 or 6 months and store in a place at 30 °C or below.
5. Preparation and Functions RC-60 • How to install dry cell batteries 1 Open the battery cover. 2 Remove the old batteries and replace with new 2xAA size dry cell batteries (alkaline) making sure each is placed in the proper direction as indicated. 3 Shut the battery cover until click sound can be heard. LS-80L • How to install dry cell batteries 1 Keep pushing the battery cover in 1 direction, and then try to slide the cover in 2 direction.The cover does not move but it will be open.
5. Preparation and Functions 5.2 How to set remote controller communication channel The same channel (1 to 9) must be set on the RL-SV2S and the RC-60 remote controller. RL-SV2S C“Setting channel” (p. 44) RC-60 The setting method is the same as for the RL-SV2S. Use the RC-60 control panel for setting. C“Setting channel” (p.
6. BASIC OPERATION 6.1 Setting Up Instrument Horizontal Rotation 1 Set the instrument to the tripod or smooth surface. 2 Press power switch (ON). After auto leveling, the laser beam will emit horizontally. The RL-SV2S automatically levels within the range of ±5° as shown below. It is also possible to set grades for the RL-SV2S in the direction of 2 axes. C7.1 Setting Grades(p. 29) on how to set grades.
6. Basic Operation 3 Press power switch on the LS-80L (ON). 4 Select the precision mode by pressing the On-Grade precision switch. C4.3 Level Sensor LS-80L(p. 15) 5 Locate the on-grade position “---” by moving the LS-80L up and down. 6 Mark the position of On-Grade index. (Top of the LS-80L is 40mm [1 9/16”] from index for offset marking.
6. Basic Operation Example Operational Install the LS-80L on a staff in the manner shown below. 154 153 152 151 150 Clamp knob 149 148 147 146 H O L D E R -6 131 9 138 137 136 135 134 Level sensor holder model 6 133 LS-80L 132 131 Vertical Rotation 1 Install the RL-SV2S on to the tripod and set so that the bubble is at the center of the vertical rotation circular level vial. 2 Press power switch . When auto leveling is complete, the laser beam will emit vertically.
6. Basic Operation 6.2 Height Alert Function When the instrument system detects a shock, this Shock is given to the instrument. function informs the operator of it. Height Alert Display • When the instrument’s installation status (height) is sharply changed by the contact of the operator or the like, this function stops auto leveling to keep the operation accuracy and informs the operator of the situation. The three lamps blink at the same time as shown at the right.
7. APPLIED OPERATION AND SETTING OF VARIOUS FUNCTIONS It is possible to set grades for the laser beam and various functions from the menu screen. 7.1 Setting Grades There are two methods to set grades on the laser beam: 1) direct entry of the grade values for the X and Y axes, and 2) matching to set grades on laser beam according to the slope of the ground on site. How to enter grade values Grade can be set in both axes, X and Y, as shown below. Grades can be set in the range indicated below.
7. Applied Operation and Setting of Various Functions Grade axes and axis symbols are as shown in the diagram below. +15% -15% Y axis X axis Minus Plus Plus Plus Minus Minus -15% Minus Plus +15% Panel side On the tripod set on level ground, grades will automatically level to approximately ±8%. When setting larger grades, tilt the RL-SV2S towards the direction of the slope to maintain within the auto leveling range.
7. Applied Operation and Setting of Various Functions How to set grades 1 Press the key and the X axis display will start flashing. It is possible to enter the grade. (Pressing the key will toggle between the X axis and Y axis.) 2 Press the 3 Press the 4 Press the key. keys and select the + or - mark. keys to change the digit position.
7. Applied Operation and Setting of Various Functions 5 Press the 6 Press the keys to increase or decrease the value of the digit. key to confirm the value. 7 When setting the grade for the Y axis, press the key. The Y axis display will start flashing. Set up the grade in the same manner as the X axis. $ • To reset the grade value while setting, press the and keys simultaneously before proceeding to step 5. • To set with the RC-60, check the transmission and reception display.
7. Applied Operation and Setting of Various Functions Example of how to set up When using the RL-SV2S after grade setting, it is necessary to accurately set the RL-SV2S to the direction of grade setting. Below is an example of how to set grades to the accurate grade setting direction.
7. Applied Operation and Setting of Various Functions 1 Set up the RL-SV2S on Point A of the on-grade line using the weight on the tripod. 2 Using the sight at the upper section of the RL-SV2S, adjust the direction on top of the tripod and roughly align the X+ direction to Point B on the standard axis. 3 Horizontally rotate the laser beam of the RL-SV2S. (X+0%,Y+0%) 4 At Point B adjust the height of the LS-80L installed on a pole, align the standard position of the LS-80L with the laser beam and fix.
7. Applied Operation and Setting of Various Functions Matching Mode (Manual Slope) This mode is used to align the grades of the laser calibration to the worked grade. 1 Horizontally rotate the laser beam of the RL-SV2S LS-80L set up at the standard height. 2 Adjust the height of the LS-80L installed on the pole and align the standard position of the LS-80L with the laser beam and fix. 3 Set up the LS-80L in step 2 on the grade surface.
7. Applied Operation and Setting of Various Functions 7 Press the keys described on the right to move the direction of laser beam to match the grade. $ • When the , , , or key is pressed, the laser beam will emit even if automatic alignment starts. • This mode can be used with the RC-60. • When the RC-60 is used in an environment in which similar radio signals (wireless LAN, etc.) are transmitted, and when the , , , or key is long-pushed in step 7, the laser beam grading may stop.
7. Applied Operation and Setting of Various Functions 7.2 Line Control (manual vertical beam alignment) The laser beam can be moved to the direction of the key during vertical rotation. $ • Only the X axis can be moved. • Allowable alignment range: ±5½ (when the instrument is set up on the 0½ surface) 1 Set the instrument. 2 Press the Power control key to turn unit on. When auto leveling is complete, the laser beam will be vertically emitted.
7. Applied Operation and Setting of Various Functions 4 Press the key. 5 Press either one of the key to move the beam right or left until it is precisely aligned to point B. The speed of laser beam movement will change according to the duration of time the key is being pressed. (The speed will change from low to high speed.
7. Applied Operation and Setting of Various Functions $ • While the key is pressed the auto-leveling beam shut-off will not operate. • This mode can be used with the Remote Controller RC-60. • When the RC-60 is used in an environment in which similar radio signals (wireless LAN, etc.) are transmitted, and when the or key is long-pushed in step 7, the laser beam grading may stop. If this interferes with the operation, change the transmission channels for the RL-SV2S and the RC-60 and try again.(C5.
7. Applied Operation and Setting of Various Functions 7.3 Setting of Various Functions Selecting MENU After pressing the key, pressing the or can be performed for the functions listed below. Safety lock ON/OFF setting Sleep Mode ON/ OFF setting key will change the menu items and setting Matching Mode Remote channel setting Masking setting Manual Mode ON/ OFF setting • For Matching Mode, see the “Matching Mode (Manual Slope)” (p. 35).
7. Applied Operation and Setting of Various Functions Masking (Laser beam shutter) setting Depending on the status of the location where the instruments are used, laser beam emission to unnecessary direction can be shut off. 1 Press 2 Use the key to display the menu screen. key to position on the Mask display and press the key. 3 Select the direction you desire to mask using the arrow keys. Each press repeats mask activating/releasing. The state when masking is not activated.
7. Applied Operation and Setting of Various Functions 4 When desired masking is displayed, press the key to finish. How to change the rotary head speed The rotary head speed can be set to 600 or 300 R.P.M. 1 Press the 2 Use the key to display the menu screen. key to select the rotary head speed (SPEEd) and press the 3 When the rotary head speed selected using the 42 keys, press the key. key to finish.
7. Applied Operation and Setting of Various Functions Switching Auto leveling / Manual Mode Auto leveling function can be canceled and switched to Manual Mode. Auto leveling OFF (LEVEL OFF): After auto leveling is complete, the auto leveling function will stop. (Manual Mode) Auto leveling ON (LEVEL ON): Auto leveling function will be effective at all times. 1 Press the 2 Press the key. or key to select auto leveling (LEVEL), and press the 3 Press the or key to select ON or OFF and press the key.
7. Applied Operation and Setting of Various Functions Setting channel When more than one RL-SV2Ss is used at the same location, change the communication channel to prevent interference. $ You may set the channel from 1 to 9. 1 Press the key to display the menu screen. 2 Press the 3 Press the or or key to select the communication channel (CH.SET) setting, and press the key to select the channel and press the key. key. Setting is complete.
7. Applied Operation and Setting of Various Functions 1 Press the 2 Press the or key and select Sleep Mode ON/OFF (SLEEP), and press the 3 Press the or key to select ON/OFF, and press the key. key. key. Setting is complete. $ There are two ways to revert from the Sleep Mode. • Press one of the keys on RC-60. • Turn OFF the power using the power key for the RL-SV2S, and turn the power back on. After reverting from the Sleep Mode, all previous settings are maintained.
7. Applied Operation and Setting of Various Functions Height Alert ON/OFF C6.2 Height Alert Function(p. 28) 1 Press the 2 Press the key. or key and select Safety Lock ON/OFF (Hl.ALr), and press the 3 Press the or key and select ON or OFF, and press the complete. 46 key. Setting is key.
8. CHECK AND ADJUSTING Please perform check and adjusting regularly. First check, and then make adjustments accordingly. 8.1 Check and Adjust Horizontal Rotation Horizontal rotation grade error Y+ • How to check X+ X- 1 Set up tripod approximately 50 meters away from a wall, and set the instrument on level with the X1 facing the wall. 2 While pressing the grade key, turn ON the power. (Only the main unit is operable). [CaLIb] will flash on the X axis screen.
8. Check and Adjusting The screen will be in the X-axis check and adjusting mode. Auto leveling on the RL-SV2S is complete and the laser will emit. 4 Turn the LS-80L to the high precision mode. 5 Detect the center of the laser beam on the wall with the LS-80L and mark it. (X1) 6 Press the key. 7 Loosen the centering screw and rotate the RL-SV2S 180°, and tighten the screw to secure. The RL-SV2S X+ surface will face the wall. When rotating the RL-SV2S, ensure that the instrument height is not misaligned.
8. Check and Adjusting 8 Detect the center of the LS-80L laser beam on the wall and mark (X2). X1 9 If the difference in height of the two laser beam marks (X1 and X2) is less than 5 mm, no adjustment is required. Turn OFF the power. If the difference is more than 5 mm, follow adjusting steps for horizontal rotation. C e How to adjust¨ð® µ°© X2 X2 laser beam X2 laser position 50m 10 Perform check on the Y axis after the adjustment for the X axis is complete.
8. Check and Adjusting • How to adjust 1 According to step 9 of the horizontal rotation check, press the keys to move the laser beam between X1 and X2. OR 2 Press the key. Adjustment for X axis is complete. Exceeding the range of adjustment. C12. Error Display(p. 62) The RL-SV2S is calculating the correction value. Do not touch the RL-SV2S until [End] is displayed. (If you touch it, you will need to readjust.
8. Check and Adjusting Horizontal Rotation Cone Error Perform the following check after completing “Horizontal Calibration” on the previous page. Approx.µ°í Cone Error Wall A Standard location Wall B Wall A Wall B 1 Set up the laser centered between two walls approximately 50 m (164 ft) apart. Orient the instrument so one axis, either X or Y, is facing the walls. Grade should be set to 0.00% in both axes. 2 Locate and mark the position of the RL-SV2S beam on both walls using the LS-80L.
8. Check and Adjusting 6 If the difference between each set of marks is less than ±5 mm (±7/32 of an inch), no error exists. G If the difference between [wall A]-side and [wall B]-side exceeds ±5 mm (±7/32 of an inch), contact your dealer or Topcon. Grade Setting Error Perform the following check only after completing “Horizontal Calibration” and “Horizontal Rotation Cone Error”. • Checking 1 Setup the X- side facing the staff as shown in the figure.
8. Check and Adjusting 2 Turn on power for the RL-SV2S and verify the staff height of Nail 1 and Nail 2 at grade setting of 0% with LS-80L and record. At this time the staff height for Nail 1 and Nail 2 should recorded as h1 and h2 (mm). Check the LS-80L is set at high precision. 3 Set Y axis grade to 1.00%. Align read the elevation of the laser beam in millimeters at Nail 1 and Nail 2. Designate these elevations as “h3” at Nail 1, and “h4” at Nail 2.
8. Check and Adjusting 8.2 Vertical Calibration Checking Calibration Beam 1 Turn ON the power for the LS-80L and move into high precision mode. 2 Install the LS-80L on a beam 10 meters or Label sensor higher above the floor, as shown in the diagram. 3 Hang the weight from the LS-80L indicator to the floor (Point A). 4 Mark the standard line on the floor perpendicular to Approx.10m the direction of the beam where Point A crosses.
8. Check and Adjusting 7 Measure the difference X between the standard line and laser beam. 8 If X is within 1 mm, no adjustment is required. If the difference exceeds 1 mm, move on to the next adjustment. Horizontal calibration and adjustment 1 Move the RL-SV2S in the direction of the arrow to align the standard line and laser beam. 2 While pressing the key, press the key. Press the key. 3 Press either the key or the key to align the laser beam with the LS-80L indicator position.
8. Check and Adjusting If the screen below is displayed, the adjustment is complete. $ If [CALIb OVEr] is displayed C12. Error Display(p.
9. STORAGE PRECAUTIONS Always clean the instrument after use. • If the instrument got wet with rain, wipe it well before storing in the storage case. • Wipe away stain or dirt with soft cloth after dusting. • Clean storage case using cloth moistened with neutral detergent or water. Do not use ether, benzene, thinner or other solvents.
10. HOW TO STORE After using the instrument, store it as shown below. LS-80L (LS-80A/80B/90) Level sensor holder model 6 (LS-B10) RL-SV2S AD-15 BT-74Q D size dry cell battery AA size dry cell battery • The LS-80A/80B/90 and LS-B10 can be stored in this carrying case (The LS-70 cannot be stored in this carrying case). • Holders other than the holder model 6 cannot be stored.
11. SPECIFICATIONS RL-SV2S Light source Laser output Safety standard for laser beam Automatic correction range : : : : Grade setting range Accuracy : : Manual slope settable range : Line control during vertical rotation: Rotation speeds : Operating range : Power supply/Operating time : Laser diode (Visible, 635nm) 2.
11. Specifications Protection against water and dust : Operating temperature : Storable temperature range : ÌÓ ÷áòîéîç äéóðìáù : Dimensions Laser beam height : : Weight : Tripod screw : IP66 (Based on the standard IEC60529) –20 °C to +50 °C (–4 °F to +122 °F) –30 °C to +60 °C (–22 °F to +140 °F) RL-SV2S height alert warning (Warning is displayed on the indicator of LS-80L.) RL-SV2S battery warning (Warning is displayed on the indicator of LS-80L.) 177 (L) × 196 (W) × 217 (H) mm [7.0 (L) × 7.
11. Specifications LS-80L (Back side display area) Beam detection window : Beam detection precision High precision : Normal precision : Beam detection indication : Power source : Operating time : Auto shut-off delay : Protection against water and dust : Operating temperature : Storage temperature : Dimensions : Weight : 50 mm (2.0 in) ±1 mm (±0.04 in) ±2 mm (±0.08 in) Liquid crystal (both sides) and buzzer 2×AA size dry cell batteries Approx. 120 hours (Using alkaline manganese dry cell batteries) Approx.
12. ERROR DISPLAY If an error is displayed, follow the procedures shown below. Error Display Description/Countermeasure If an error is displayed, follow the procedures shown below. C6.2 Height Alert Function(p. 28) RL-SV2S setting exceeds the leveling range. Reset tilting to the direction to raise the X+ side. Reset tilting to the direction to raise the X- side. Alternate flashing Reset tilting to the direction to raise the Y+ side. OR Reset tilting to the direction to raise the Y- side.
12. Error Display Error Display Description/Countermeasure Transmission error with remote control. Change both the RL-SV2S and RC-60 to other channel. If the error persists, check the transmission environment and reduce wireless LAN and other similar wireless transmissions as much as possible. More than 2 RL-SV2S devices are within the transmission range of the RC-60, making transmission impossible. Change the channel for both the RL-SV2S (1) and RC-60 used for the operation to another channel.
12. Error Display Error Display E-51,55 Description/Countermeasure Internal error Transmission not possible with the RL-SV2S. Remove and replace the dry cell batteries from the RC-60. Wireless function error for the RL-SV2S. Unable to transmit with the RC-60. Turn the power for the instrument off, and then turn it back on. E-?? E-65 Internal transmission error for the RL-SV2S. Turn the power for the instrument off, and then turn it back on. E-70’s Slope function error.
13. REGULATIONS Region/ Country Directives/ Regulations Labels/Declarations FCC Compliance This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Contains FCC ID: XXXXXXXX(RL-SV2S)/XXXXXXX(RC-60) NOTE: U.S.A.
13. Regulations WARNING: Change or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Specified cables must be used for connection to computer and/or peripherals in order to meet FCC emission limits. CAUTION: This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter. End user cannot modify this transmitter device.
13. Regulations Region/ Country California, U.S.A.
13. Regulations California, and NY, U.S.A.
13. Regulations Region/ Country Directives/ Regulations Labels/Declarations Contains IC: XXXXX-XXXXX(RL-SV2S)/XXXXX-XXXXX(RC-60) The term “IC:” before the radio certification number only signifies that Industry Canada technical specifications were met. Canada ICES “Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
13. Regulations Region/ Country Directives/ Regulations Australia C-Tick EU R&TTE CE Labels/Declarations The compliance label indicates that the product complies with the applicable standard and establishes a traceable link between the equipment and the manufacturer, importer or their agent responsible for compliance and for placing it on the Australian market. R&TTE Directive EU 70 R&TTE ROTATING LASER RL-SV2S, REMOTE CONTROLLER RC-60 Hereby, TOPCON CORP.
13.