Product Manual
Point Properties window
MAGNET Tools ver 1.0
77
Adjustment Tab of the Properties
Window for a Point
You can open this tab if the Properties command from the pop-up
menu for the highlighted line in the Point tab
is selected. This tab
contains the fields:
• Standard Deviations – the standard deviations for the point after
adjustment. Std Dev n
, Std Dev e, Std Dev Hz, Std Dev u are
displayed in Grid (N/E/U) coordinate system.
• Error Ellipse Azimuth
- stands for the azimuth of the major semi-
axis of the error ellipse for the given point after adjustment. This
value depends on the current Confidence Level.
• Error Ellipse major semi-axis - displays the length of the major
semi-axis of the error ellipse for the given point after adjustment.
This value depends on the current Confidence Level
.
• Error Ellipse minor semi-axis
- displays the length of the minor
semi-axis of the error ellipse for the given point after adjustment.
This value depends on the current Confidence Level.
Quality Control Tab of the Properties Window
for a Point
You can open this tab, if the Properties command from the pop-up
menu for the highlighted line in the Point tab
was selected. The
Quality Control tab contains:
• pane with information
about highlighted points (marked in red on
the views) that did not pass some of the quality control checks.
• check box Ignore QC
- if this parameter is checked, all quality
control tests are not performed for the given point. This
parameter is unchecked by default.