Product Manual

Process Item of the Job Configuration Window
MAGNET Tools ver 1.0
23
A priori UWE tab of the Adjustment Properties
In the tab you can select as a priory the unit of weight error for the
GPS vector in vertical, horizontal or 3D adjustment, and for slope
distance, horizontal angle, and vertical angle of TS measurements in
network adjustment. The default confidence level is 1. You can edit a
value in any field of the tab. The tab contains the following fields:
GPS vector (3D) or GPS Horizontal field
- displays the current
value of the unit of weight error for the vector in horizontal
adjustment or in 3D-adjustment.
GPS vector, Vertical
- displays the current value of the unit of
weight error for the vector in vertical adjustment.
TS Measurement, SD
- displays the current value of the unit of
weight error for the Slope Distance in Total Station measurement.
TS Measurement, HA
- displays the current value of the unit of
weight error for the Horizontal Angle in Total Station
measurement.
TS Measurement, VA
- displays the current value of the unit of
weight error for the Vertical Angle in Total Station measurement.
Note: Changing a priory UWE affects the blunder search
algorithm and does not affect the final point precision.
TS Computations Properties
In the TS Computations tab you can set the Refraction Coefficient for
calculating TS point coordinates from TS raw data and can