Product Manual

Online Activation
MAGNET Tools ver 1.0
9
automatically opened. In the page enter the temporary
password in the Old password
field and a new password
in the New password
field and Confirm new field. After
clicking Next the application replaces the temporary
password by the new password.
8. The Enterprise logon
page will display. See the first
method of the activation to continue.
Job Configuration
Window
The Job configuration window allows you to define application
settings for data viewing, adjusting, and analysis. To obtain an access
to these settings, you can do one of the following:
- click
Job and click the icon in the Information
group,
- click the Edit configuration
button on the Create a new job
window.
The window contains two panels. The left panel
of the window
displays the items used to configure a job. The right panel of the
dialog box displays parameters for the selected item.
The application contains a list of default configurations, where
each configuration has a specific set of job parameters. To see
this list, click the List configuration
button. The default
configurations differ in the current coordinate type (Ground or
Datum Lat, Lon, Ell. H), precisions and automatically test for
Points, GPS Obs, TS Obs, DL Obs, and Loop Closure:
TS configuration - for processing and adjusting Total Station and
Digital Level raw data. The threshold value of precision for a
distance is 0.03 meters and 0°00'10.0000" for vertical/horizontal
angles.