Product Manual

DL Obs Properties in the Right Panel
MAGNET Tools ver 1.0
107
You can open this tab after the
Properties command from the pop-up
menu for the highlighted line in the right panel of the DL Obs tab is
selected. This tab contains the fields:
Type
- the current type of the Digital Level observation. This
field contains the list of the DL observation types. You
cannot select a type from the list:
- SS - sideshot - the measurement to a sideshot point.
- BS - backsight - the measurement to the previous
occupation point in the DL run.
- FS - foresight - the measurement to the next occupation
point in the DL run.
- End of Changing Pt - the end measurement (of the given DL
run) to the point that is used to carry the measurements
forward in the DL run.
- End of Bench Mark - the end measurement (of the given DL
run) to the point with a known elevation.
Point
- the name of a turning or side shot point. You can select a
point from the list.
Ht. Measurements
- the rod reading on the given point in the
current linear units. You cannot edit the measurement.
Vert Offset
- the vertical offset from the horizontal plane for
traverse and sideshot points.You can edit the measurement.
Distance
- the measured distance from the DL to the given point.
You cannot edit the measurement.
Instrument Elevation
- the elevation of sight that includes the
elevation of the BS point and the rod reading on the BS point.
You cannot edit the measurement.
Std Dev
- standard deviation for the level measurement. This
value is created in the Digital Level. You cannot edit the
parameter.