Product Manual
Properties Window
MAGNET Tools ver 1.0
102
• HDist Residual
- displays the residual of the horizontal distance
after adjustments for both enabled and disabled TS observations.
• VDist Residual
- displays the residual of the vertical distance
after adjustments for both enabled and disabled TS observations.
• Cross Residual
– displays the residual of the horizontal angle
represented in linear measure after adjustments for both enabled
and disabled TS observations.
Note 1: Zero value in the Res fields means that the TS observation is
included in the unclosed network and does not contain repeated TS
observations.
Note 2: The residuals for the disabled TS observation (the
observation is not included into the adjustment) are calculated as
differences between the values determined from the inverse solution
for the adjusted points and the values of measured angles and
distance.
Properties Window: Quality Control
Tab for a TS Observation
You can open this tab after selecting the Properties command from
the pop-up menu for the highlighted line in the TS Obs tab
. The
Quality Control tab contains:
• pane with information
about highlighted TS observation (marked
in red on the views) that did not pass some quality control checks.
• I
gnore QC check box - if this parameter is checked, all quality
control tests are not performed for the given TS observation. This
parameter is unchecked by default.
Properties Window: Image Tab for a
TS Occupation
Displays the image(s) for the selected TS occupation in the panel.