Product Manual

TS Obs Properties in the Right Panel
MAGNET Tools ver 1.0
101
Properties Window: Adjustment Tab
for a TS Observation
You can open this tab after selecting the Properties command from
the pop-up menu for the highlighted line in the TS Obs tab
. This tab
contains adjustment residuals for this observation in the current units.
These values depend on the current Confidence Level
.
AutoReject
- In this field you can select the status of the given TS
observation for Adjustment:
- Allowed - the TS observation will be used in Adjustment.
- Not Allowed - the TS observation will not be used in
Adjustment.
Adjustment Status
- the status of the given GPS observation after
Adjustment:
- Not Adjusted - the TS observation is not adjusted.
- Adjusted - the TS observation is adjusted.
- AutoRejected - the TS observation is not adjusted, because
the vector had the status Not Allowed before the adjustment
procedure.
- Disable - the TS observation is not adjusted, because the
vector was disabled before the adjustment procedure.
SDist Residual
- displays the residual of the slope distance after
adjustments for both enabled and disabled TS observations.
HAngle Residual
– displays the residual of the horizontal angle
after adjustments for both enabled and disabled TS observations.
Azimuth Residual
- displays the residual of the azimuth after
adjustments for both enabled and disabled TS observations.
VAngle Residual
- displays the residual of the vertical angle after
adjustments for both enabled and disabled TS observations.
ZAngle Residual
- displays the residual of the zenith angle after
adjustments for both enabled and disabled TS observations.