Product Manual
7. APPLIED OPERATION AND SETTING OF VARIOUS FUNCTIONS
30
Grade axes and axis symbols are as shown in the diagram below.
On the tripod whose head is horizontally placed, grades will automatically level to approximately
±8%. When setting larger grades, tilt the RL-SV2S towards the direction of the slope to maintain
within the auto leveling range. When exceeding the auto leveling range, the error message
"Exceeding leveling range" will be displayed.C12. ERROR DISPLAY(p. 65)
G
If you set grades by placing the RL-SV2S in a place where temperature suddenly changes, let
the instrument stand for about 10 minutes to allow it to adjust to the temperature prior to actual
use.
When temperature changes 5°C or more after setting a grade,
temperature difference is detected and the grade is corrected
automatically. During auto correction, laser will stop temporarily
(and [AUTO CALIb] will be displayed). When auto correction is
completed, the display will return to the grade setting, and after auto
leveling, laser will emit.
+15%
Y axis X axis
-15%
Panel side
Minus
Plus
Minus
Minus
Plus
Plus
Minus
Plus
-15%
+15%