INSTRUCTION MANUAL ROTATING LASER RL-SV2S 31366 90032
FOREWORD Thank you for selecting the TOPCON instrument. • Please read this instruction manual carefully before using this instrument. • Verify that all equipment is included. C “ STANDARD SYSTEM COMPONENTS” (p. iii) • The specifications and general appearance of the instrument are subject to change without prior notice and without obligation by Topcon Corporation and may differ from those appearing in this manual. • Some of the diagrams shown in this manual may be simplified for easier understanding.
HOW TO READ THIS MANUAL XSymbols The following conventions are used in this manual. Indicates precautions and important items which should be read before : G operations. C : Indicates the chapter title to refer to for additional information. $ : Indicates supplementary explanation.
STANDARD SYSTEM COMPONENTS Rechargeable battery type Dry battery type 1) RL-SV2S Instrument .......................................1pc. 2) Remote controller RC-60 (with AA Manganese battery x 2pcs.) .............1pc. 3) Level Sensor LS-80L.......................................1pc. 4) Model-6 Level Sensor Holder .........................1pc. 5) Battery holder DB-74C ....................................1pc. 6) Ni-MH battery pack BT-74Q ............................1set 7) AC/DC converter AD-15 .............
CONTENTS FOREWORD ................................................................................................................................. I HOW TO READ THIS MANUAL................................................................................................... II STANDARD SYSTEM COMPONENTS ...................................................................................... III CONTENTS .............................................................................................................
CONTENTS RC-60........................................................................................................................ 23 LS-80L....................................................................................................................... 23 5.2 How to set remote controller communication channel .................................................. 24 RL-SV2S ...................................................................................................................
CONTENTS 8. 9. 10. 11. 12. 13. vi Switching Auto leveling / Manual Mode .................................................................... 46 Setting channel ......................................................................................................... 47 Sleep mode............................................................................................................... 48 Height Alert ON/OFF.......................................................................................
1. PRECAUTIONS FOR SAFE OPERATION For the safe use of the product and prevention of injury to operators and other persons as well as prevention of property damage, items which should be observed are indicated by an exclamation point within a triangle used with WARNING and CAUTION statements in this instruction manual. The definitions of the indications are listed below. Be sure you understand them before reading the manual’s main text.
1. PRECAUTIONS FOR SAFE OPERATION General Warning Do not perform disassembly or rebuilding. Fire, electric shock or burns could result. Do not use the unit in areas exposed to high amounts of dust or ash, in areas where there is inadequate ventilation, or near combustible materials. An explosion could occur. When securing the instrument in the carrying case make sure that all catches, including the side catches, are closed.
1. PRECAUTIONS FOR SAFE OPERATION Power Supply Warning Do not short circuit. Heat or ignition could result. Do not use voltage other than the specified power supply voltage. Fire or electrical shock could result. Do not use damaged power cords, plugs or loose outlets. Fire or electric shock could result. Do not use power cords other than those designated. Fire could result. Do not use batteries other than those designated. An explosion could occur, or abnormal heat generated, leading to fire.
1. PRECAUTIONS FOR SAFE OPERATION Do not heat or throw batteries into fire. An explosion could occur, resulting in injury. Do not use the battery or charger for any other equipment or purpose. Fire or burns caused by ignition could result. To prevent shorting of the battery in storage, apply insulating tape or equivalent to the terminals. Otherwise shorting could occur, resulting in fire or burns. Do not use batteries or the battery charger if wet. Resultant shorting could lead to fire or burns.
1. PRECAUTIONS FOR SAFE OPERATION Tripod Caution When mounting the instrument to the tripod, tighten the centering screw securely. Failure to tighten the screw properly could result in the instrument falling off the tripod, causing injury. Tighten securely the leg fixing screws of the tripod on which the instrument is mounted. Failure to tighten the screws could result in the tripod collapsing, causing injury. Do not carry the tripod with the tripod shoes pointed at other persons.
2. PRECAUTIONS Before starting work or operation, be sure to check that the instrument is functioning correctly with normal performance. Vibration and Impact Protection When transporting the instrument, provide protection to minimize risk of severe vibration or impact. Severe vibration or impacts may affect beam accuracy. Sudden changes of temperature A sudden change in temperature may cause water condensation on the glass used for the laser emission part.
2. PRECAUTIONS • The manufacturer, or its representatives, assumes no responsibility for results of a faulty or intentional usage or misuse including any direct, indirect, consequential damage, and loss of profits. • The manufacturer, or its representatives, assumes no responsibility for consequential damage, and loss of profits by any disaster, (an earthquake, storms, floods etc.). A fire, accident, or an act of a third party and/or a usage any other usual conditions.
3. LASER SAFETY INFORMATION The RL-SV2S is classified as a class 3R Laser Product according to IEC Standard Publication 60825-1 Ed.2.0: 2007 and United States Government Code of Federal Regulation FDA CDRH 21CFR Part1040.10 and 1040.11 (Complies with FDA performance standards for laser products except for deviations pursuant to Laser Notice No.50, dated June 24, 2007.) Laser Safety This product projects a visible laser beam during operation.
3. LASER SAFETY INFORMATION Visible laser Laser output: 2.4mW Beam aperture Explanatory Label Each label is differed by the market. Warning Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. Do not look directly into the laser beam. Doing so could cause permanent eye damage.
3. LASER SAFETY INFORMATION Do not stare at the laser beam. Doing so could cause permanent eye damage. If an eye injury is caused by exposure to the laser beam, seek immediate medical attention from a licensed ophthalmologist. Caution Perform checks at start of work and periodic checks and adjustments with the laser beam emitted under normal conditions. When the instrument is not being used, turn off the power.
4. NOMENCLATURE 4.
4. NOMENCLATURE RC-60 Nomenclature Display Menu key/Escape key Arrow keys Enter key X/Y axis selection key/Alignment key/ Up key Strap hole • Turn ON the power of the RL-SV2S before using the RC-60. Pressing one of the keys (or inserting the battery) will display the channel search (CH SErCH) and begin transmission with the RL-SV2S. • When the channel is not aligned with the RL-SV2S or when the RL-SV2S power is not turned ON, the display will show "Transmission error with remote control" (p. 66).
4. NOMENCLATURE • The RC-60 is a remote controller specifically designed for the RL-SV2S and cannot be used with other models. RL-SV2S/RC-60 Key Operation Key Nomenclature Function Enter key End Operation of Data Input and Sends data to the instrument. Menu/Escape key Selects a menu item. Cancels input or escape to previous status. X/Y axis selection key/ Alignment key Horizontal rotation: changes to the grade setting screen for each axis. Vertical rotation: changes to the Alignment Mode.
4.
4. NOMENCLATURE 4.2 Level Sensor LS-80L LS-80L Nomenclature Power switch The power switch turns ON or OFF by pressing. On-Grade precision switch Two on-grade precision options are available, normal precision (±2mm) and high precision (±1mm). By pressing this switch, the precision options are switched alternately. Confirm the precision choice by the indicator. (Normal precision is the default setting each time the sensor is turned on.
4. NOMENCLATURE LS-80L Display Height alert warning of rotating laser*1 A flash and a buzzer sound signifies that the height alert function of the RL-SV2S is operating. High precision mode Normal precision mode Higher than datum position (Buzzer sound:High frequent beep sound) Move the sensor downward. Datum position Rotating laser battery warning*2 (Buzzer sound:Continuous beep sound) Lower than datum position A flash shows that the RL-SV2S power is low.
4.
5. PREPARATION AND FUNCTIONS 5.1 Power Source Connect the battery according to the battery type purchased. RL-SV2S (Dry battery type) • How to install dry cell batteries 1 Remove the DB-74 battery holder by turning battery holder knob to "OPEN" side. 2 Install the new 4xD size dry cell batteries (alkaline) referring to the illustration on the DB-74 battery holder.*1), *2), *3) 3 Install the battery holder. Tighten the battery cover knob to "LOCK" side.
5. PREPARATION AND FUNCTIONS • How to remove dry cell batteries 1 Remove the DB-74 battery holder by turning battery holder knob to "OPEN" side. 2 Remove the dry cell batteries from the DB-74 battery holder. G *1 Replace all 4 batteries with new ones at the same time. Do not mix used and new batteries, and do not mix different types of batteries together. *2 Use alkaline dry cells. (Dry cells for movement confirmation are packed in shipment.
5. PREPARATION AND FUNCTIONS RL-SV2S (Rechargeable battery type) • How to install the battery pack BT-74Q 1 Insert the battery pack BT-74Q into the DB-74C battery holder in the direction shown in the diagram on the right. 2 Install the battery holder. Tighten the battery cover knob to "LOCK" side. DB-74C • How to remove the battery pack 1 Remove the DB-74C battery holder by turning battery holder knob to "OPEN" side.
5. PREPARATION AND FUNCTIONS • For Charging Plug AD-15 1 Plug the AC/DC converter (AD-15) into the DB-74C battery holder or plug the AD-15 into the battery pack BT-74Q. 2 Insert the AD-15 power cord in an outlet. 3 Complete charging by unplugging the plug from the DB-74C battery holder or battery pack BT-74Q after approximately 13 hours. 4 Unplug the AD-15 power cord from the outlet.
5. PREPARATION AND FUNCTIONS G • Recharging should take place in a room with an ambient temperature range of 10°C to 40°C (50°F to 104°F). • Do not perform charging with others except the AC/DC converter AD-15. • For longer battery life, conform to the suggested charging time to the extent possible. • The battery source will discharge when stored and should be checked before using with instrument. • Do not recharge the battery when fully charged. Doing so will lower battery performance.
5. PREPARATION AND FUNCTIONS RC-60 • How to install dry cell batteries 1 Open the battery cover. 2 Remove the old batteries and replace with new 2xAA size dry cell batteries (alkaline) making sure each is placed in the proper direction as indicated. 3 Shut the battery cover until click sound can be heard. LS-80L • How to install dry cell batteries 1 Keep pushing the battery cover in 1 direction, and then try to slide the cover in 2 direction.The cover does not move but it will be open.
5. PREPARATION AND FUNCTIONS 5.2 How to set remote controller communication channel The same channel (1 to 9) must be set on the RL-SV2S and the RC-60 remote controller. RL-SV2S CSetting channel (p. 47) RC-60 The setting method is the same as for the RL-SV2S. Use the RC-60 control panel for setting. CSetting channel (p. 47) When the channel is not aligned with the RL-SV2S, the display will show "Transmission error with remote control" (p. 66).
6. BASIC OPERATION 6.1 Setting Up Instrument Horizontal Rotation 1 Set the instrument to the tripod or smooth surface. 2 Press power switch (ON). Auto leveling will begin. After the auto leveling, the laser beam will emit horizontally. The RL-SV2S automatically levels within the range of ±5° as shown below. It is also possible to set grades for the RL-SV2S in the direction of 2 axes. C7.1 Setting Grades(p. 29) on how to set grades.
6. BASIC OPERATION 3 Press power switch on the LS-80L (ON). 4 Select the precision mode by pressing the On-Grade precision switch. C4.2 Level Sensor LS-80L(p. 15) 5 Locate the on-grade position “---” by moving the LS-80L up and down. 6 Mark the position of On-Grade index. (Top of the LS-80L is 40mm [1 9/16”] from index for offset marking.
6. BASIC OPERATION Example Operational Install the LS-80L on a staff in the manner shown below. 154 153 152 151 150 Clamp knob 149 148 147 146 H O L D E R -6 131 9 138 137 136 135 134 Level sensor holder model 6 133 LS-80L 132 131 Vertical Rotation 1 Install the RL-SV2S on to the tripod and set so that the bubble is at the center of the vertical rotation circular level vial. 2 Press power switch . When auto leveling is complete, the laser beam will emit vertically.
6. BASIC OPERATION 6.2 Height Alert Function When the instrument system detects a shock, this Shock is given to the instrument. function informs the operator of it. Height Alert Display • When the instrument’s installation status (height) is sharply changed by the contact of the operator or the like, this function stops auto leveling to keep the operation accuracy and informs the operator of the situation.
7. APPLIED OPERATION AND SETTING OF VARIOUS FUNCTIONS It is possible to set grades for the laser beam and various functions from the menu screen. 7.1 Setting Grades There are two methods to set grades on the laser beam: 1) direct entry of the grade values for the X and Y axes, and 2) matching to set grades on laser beam according to the slope of the ground on site. How to enter grade values Grade can be set in both axes, X and Y, as shown below. Grades can be set in the range indicated below.
7. APPLIED OPERATION AND SETTING OF VARIOUS FUNCTIONS Grade axes and axis symbols are as shown in the diagram below. Y axis +15% Minus Plus Plus Minus X axis Plus Minus -15% -15% Minus Plus +15% Panel side On the tripod whose head is horizontally placed, grades will automatically level to approximately ±8%. When setting larger grades, tilt the RL-SV2S towards the direction of the slope to maintain within the auto leveling range.
7. APPLIED OPERATION AND SETTING OF VARIOUS FUNCTIONS How to set grades 1 Press the key and the X axis display will start flashing. It is possible to enter the grade. (Pressing the key will toggle between the X axis and Y axis.) 2 Press the 3 Press the 1 Press the key and select the axis to reset the grade value. 2 Press both the keys simultaneously to reset the grade value. 3 Pressing the key will switch to the mark selection state. 4 Press the key.
7. APPLIED OPERATION AND SETTING OF VARIOUS FUNCTIONS 5 Press the 6 Press the keys to increase or decrease the value of the digit. key to confirm the value. 7 When setting the grade for the Y axis, press the key. The Y axis display will start flashing. Set up the grade in the same manner as the X axis. $ • To set with the RC-60, check the transmission and reception display.
7. APPLIED OPERATION AND SETTING OF VARIOUS FUNCTIONS Example of how to set up When setting grade, it is necessary to accurately set the RL-SV2S to the direction of grade setting. Below is an example of how to set grades to the accurate grade setting direction.
7. APPLIED OPERATION AND SETTING OF VARIOUS FUNCTIONS 1 Set up the RL-SV2S on Point A of the base line using the plumb bob on the tripod. 2 Using the sight at the upper section of the RL-SV2S, adjust the direction on top of the tripod and roughly align the X+ direction to Point B on the standard axis. 3 Horizontally rotate the laser beam of the RL-SV2S. (X+0.000%, Y+0.
7. APPLIED OPERATION AND SETTING OF VARIOUS FUNCTIONS Matching Mode (Manual Slope) This mode is used to align the grades of the laser calibration to the worked grade. 1 Horizontally rotate the laser beam of the RL-SV2S set up at the standard height. (X+0.000%, Y+0.000%) LS-80L 2 Adjust the height of the LS-80L installed on the pole and align the standard position of the LS-80L with the laser beam and fix. 3 Set up the LS-80L in step 2 on the grade surface.
7. APPLIED OPERATION AND SETTING OF VARIOUS FUNCTIONS 7 Confirm that auto leveling is complete and that the laser beam is emitting. Press the arrow key ( :To align with grade on the X- side) once in the desired direction to align grades, and the laser beam will continue to lean toward the direction of the key. The arrow key cannot be used until auto leveling is complete and the laser beam starts emitting.
7. APPLIED OPERATION AND SETTING OF VARIOUS FUNCTIONS align with the standard position for the LS-80L. The length of time the arrow key is pressed will change the speed at which the laser beam grades. (The speed will change from low to high speed.) For Y-axis grading, follow steps 7 to 9 using keys. * Display during arrow key operation The laser beam is moving in the X (Y) + direction. The laser beam is moving in the X (Y) - direction.
7. APPLIED OPERATION AND SETTING OF VARIOUS FUNCTIONS [Display during the Matching Mode] is flashing SLOPE LEVEL : in the Matching Mode. It is possible to adjust the grade of the laser beam with arrow keys. When a certain amount of time has passed after the arrow key operation, the light that was flashing will remain lit. Grading cannot be adjusted when is on. : shows the axis on which the grading is being adjusted. : shows the axis that is being graded.
7. APPLIED OPERATION AND SETTING OF VARIOUS FUNCTIONS 7.2 Line Control (manual vertical beam alignment) The laser beam can be moved to the direction of the key during vertical rotation. $ • Only the X axis can be moved. • Allowable alignment range: ±5° (when the instrument is set up on the 0° surface) 1 Set the instrument. 2 Press the Power control key to turn unit on. When LS-80L autoleveling is complete, the laser beam will be rotate vertically.
7. APPLIED OPERATION AND SETTING OF VARIOUS FUNCTIONS 4 Press the key to enter the Line Control Mode. is flashing :in the Line Control Mode. It is possible to adjust the laser beam with key. When a certain amount of time has passed after the key operation, the light that was flashing will remain lit. The laser beam cannot be adjusted when the light is on. LEVEL is flashing :performing auto leveling in the vertical direction. 5 Confirm that auto leveling is complete and that the laser beam is emitting.
7. APPLIED OPERATION AND SETTING OF VARIOUS FUNCTIONS Direction of laser beam movement when operating Key Display* key Direction of laser beam movement XX- X+ X+ C * Display during arrow key operation (p. 37) When readjusting with line control, return to step 4 and follow directions thereafter. In such a case, however, skip steps 5 and 6. $ • During the vertical rotation or the manual line control, the laser beam will emit even if auto leveling starts.
7. APPLIED OPERATION AND SETTING OF VARIOUS FUNCTIONS • This mode can be used with the Remote Controller RC-60. • When the RC-60 is used in an environment in which similar radio signals (wireless LAN, etc.) are transmitted, and when the or key is long-pushed in step 7, the laser beam grading may stop. If this interferes with the operation, change the transmission channels for the RL-SV2S and the RC-60 and try again. C5.2 How to set remote controller communication channel(p.
7. APPLIED OPERATION AND SETTING OF VARIOUS FUNCTIONS 7.3 Setting of Various Functions Selecting MENU After pressing the key, pressing the or can be performed for the functions listed below. Safety lock ON/OFF setting Sleep Mode setting This menu is only available for the RC-60. key will change the menu items and setting Matching Mode Remote channel setting Masking setting Manual Mode ON/ OFF setting Speed setting • For Matching Mode, see the Matching Mode (Manual Slope) (p. 35).
7. APPLIED OPERATION AND SETTING OF VARIOUS FUNCTIONS Masking (Laser beam shutter) setting Depending on the status of the location where the instruments are used, laser beam emission to unnecessary direction can be shut off. 1 Press 2 Use the key to display the menu screen. key to position on the Mask display and press the key. 3 Select the direction you desire to mask using the arrow keys. Each press repeats mask activating/releasing. The state when masking is not activated.
7. APPLIED OPERATION AND SETTING OF VARIOUS FUNCTIONS 4 When desired masking is displayed, press the key to finish. How to change the rotary head speed The rotary head speed can be set to 600 or 300 R.P.M. 1 Press the 2 Use the key to display the menu screen. key to select the rotary head speed (SPEEd) and press the 3 When the rotary head speed selected using the keys, press the key. key to finish.
7. APPLIED OPERATION AND SETTING OF VARIOUS FUNCTIONS Switching Auto leveling / Manual Mode Auto leveling function can be canceled and switched to Manual Mode. Auto leveling OFF (LEVEL OFF): After auto leveling is complete, the auto leveling function will stop. (Manual Mode) Auto leveling ON (LEVEL ON): Auto leveling function will be effective at all times. 1 Press the 2 Press the key.
7. APPLIED OPERATION AND SETTING OF VARIOUS FUNCTIONS Setting channel When more than one RL-SV2Ss is used at the same location, change the communication channel to prevent interference. $ You may set the channel from 1 to 9. 1 Press the key to display the menu screen. 2 Press the or press the 3 Press the key to select the communication channel (CH.SET) setting, and key. or key to select the channel and press the To shift to other modes, press the key. Setting is complete. key.
7. APPLIED OPERATION AND SETTING OF VARIOUS FUNCTIONS Sleep mode When the Sleep Mode is turned ON with the RC-60, the RL-SV2S will change to the Standby Mode (Laser OFF, head rotation OFF and auto leveling OFF). 1 Press the 2 Press the key. 3 Press the key. Setting is complete. or key and select Sleep Mode (SLEEP), and press the key. $ There are two ways to revert from the Sleep Mode. • Press one of the keys on RC-60.
7. APPLIED OPERATION AND SETTING OF VARIOUS FUNCTIONS Height Alert ON/OFF C6.2 Height Alert Function(p. 28) 1 Press the 2 Press the key. or key and select Safety Lock ON/OFF (Hl.ALr), and press the 3 Press the or key and select ON or OFF, and press the key. key. Setting is complete. To shift to other modes, press the key.
8. CHECK AND ADJUSTING Please perform check and adjusting regularly. First check, and then make adjustments accordingly. 8.1 Check and Adjust Horizontal Rotation Horizontal Rotation Grade Error Y+ • How to check X+ X- 1 Set up tripod approximately 50 meters away from a wall, and set the instrument on level with the X1 facing the wall. 2 While pressing the key, turn ON the power. (Only the RL-SV2S is operable). [CaLIb] will flash on the X axis screen.
8. CHECK AND ADJUSTING The screen will be in the X-axis check and adjusting mode. Auto leveling on the RL-SV2S is complete and the laser will emit. 4 Turn the LS-80L to the high precision mode. 5 Detect the center of the laser beam on the wall with the LS-80L and mark it. (X1) 6 Press the key. 7 Loosen the centering screw and rotate the RL-SV2S 180°, and tighten the screw to secure. The RL-SV2S X+ surface will face the wall. When rotating the RL-SV2S, ensure that the instrument height is not misaligned.
8. CHECK AND ADJUSTING 8 Detect the center of the LS-80L laser beam on the wall and mark (X2). X1 9 If the difference in height of the two laser beam marks (X1 and X2) is less than 5 mm, no adjustment is required. Turn OFF the power. If the difference is more than 5 mm, follow adjusting steps for horizontal rotation. CHow to adjust (p. 53) X2 X2 laser beam 50m X2 laser position 10 Perform check on the Y axis after the adjustment for the X axis is complete.
8. CHECK AND ADJUSTING • How to adjust 1 According to step 9 of the horizontal rotation check, press the keys* to move the laser beam between X1 and X2. * When adjusting the Y axis direction, press the OR 2 Press the keys. C * Display during arrow key operation (p. 37) key. Adjustment for X axis is complete. Turn OFF the power. Exceeding the range of adjustment. C12. ERROR DISPLAY(p. 65) The RL-SV2S is calculating the correction value. Do not touch the RL-SV2S until [End] is displayed.
8. CHECK AND ADJUSTING Horizontal Rotation Cone Error Perform the following check after completing “Horizontal Rotation Grade Error” on the previous page. Approx.50m Cone Error Wall A Standard location Wall B Wall A Wall B 1 Set up the laser centered between two walls approximately 50 m (164 ft) apart. Orient the instrument so one axis, either X or Y, is facing the walls. Grade should be set to 0% in both axes. 2 Locate and mark the position of the RL-SV2S beam on both walls using the LS-80L.
8. CHECK AND ADJUSTING 6 If the difference between each set of marks is less than ±5 mm (±7/32 of an inch), no error exists. G If the difference between [wall A]-side and [wall B]-side exceeds ±5 mm (±7/32 of an inch), contact your dealer or Topcon. Grade Setting Error Perform the following check only after completing “Horizontal Rotation Grade Error” and “Horizontal Rotation Cone Error”. • Checking 1 Setup the X- side facing the staff as shown in the figure.
8. CHECK AND ADJUSTING 2 Turn on power for the RL-SV2S and verify the staff height of Nail 1 and Nail 2 at grade setting of 0% with LS-80L and record. At this time the staff height for Nail 1 and Nail 2 should recorded as h1 and h2 (mm). Check the LS-80L is set at high precision. 3 Set X axis grade to +1.000%. Align read the elevation of the laser beam in millimeters at Nail 1 and Nail 2. Designate these elevations as “h3” at Nail 1, and “h4” at Nail 2.
8. CHECK AND ADJUSTING 8.2 Vertical Calibration Checking Calibration Beam 1 Turn ON the power for the LS-80L and move into high precision mode. 2 Install the LS-80L on a beam 10 meters or Level sensor higher above the floor, as shown in the diagram. 3 Hang the plumb bob from the LS-80L indicator to the floor (Point A). 4 Mark the standard line on the floor perpendicular to Approx.10m the direction of the beam where Point A crosses.
8. CHECK AND ADJUSTING 7 Measure the difference X between the standard line and laser beam. 8 If X is within 1 mm, no adjustment is required. If the difference exceeds 1 mm, move on to the next adjustment. Vertical calibration and adjustment 1 While pressing the Press the key, press the key. key. 2 Move the RL-SV2S in the direction of the arrow to align the standard line and laser beam. 3 Press either the key or the key to align the laser beam with the LS-80L indicator position.
8. CHECK AND ADJUSTING 4 Press the key. If the screen below is displayed, the adjustment is complete. Turn OFF the power. The RL-SV2S is calculating the correction value. Do not touch the RL-SV2S until [End] is displayed. (If you touch it, you will need to readjust.) $ If [CALIb OVEr] is displayed C12. ERROR DISPLAY(p.
9. STORAGE PRECAUTIONS Always clean the instrument after use. • If the instrument got wet with rain, wipe it well before storing in the storage case. • Wipe away stain or dirt with soft cloth after dusting. • Clean storage case using cloth moistened with neutral detergent or water. Do not use ether, benzene, thinner or other solvents.
10. HOW TO STORE After using the instrument, store it as shown below. RC-60 LS-80L (LS-80A/80B/90) Level sensor holder model 6 (LS-B10) RL-SV2S AD-15 BT-74Q D size dry cell battery AA size dry cell battery • The LS-80A/80B/90 and LS-B10 can be stored in this carrying case (The LS-70 cannot be stored in this carrying case). • Holders other than the holder model 6 cannot be stored.
11. SPECIFICATIONS RL-SV2S Light source Laser output Safety standard for laser beam Automatic correction range : : : : Grade setting range Accuracy : : Manual slope settable range : Line control during vertical rotation: Rotation speeds : Operating range : Power supply/Operating time : 62 Laser diode (Visible, 635nm) 2.
11. SPECIFICATIONS Protection against water and dust : Operating temperature : Storable temperature range : LS warning display : Dimensions Laser beam height : : Weight : Tripod screw : IP66 (Based on the standard IEC60529) –20 °C to +50 °C (–4 °F to +122 °F) –30 °C to +60 °C (–22 °F to +140 °F) RL-SV2S height alert warning (Warning is displayed on the indicator of LS-80L.) RL-SV2S battery warning (Warning is displayed on the indicator of LS-80L.) 177 (L) × 196 (W) × 217 (H) mm [7.0 (L) × 7.
11. SPECIFICATIONS LS-80L (Back side display area) Beam detection window : Beam detection precision High precision : Normal precision : Beam detection indication : Power source : Operating time : Auto shut-off delay : Protection against water and dust : Operating temperature : Storage temperature : Dimensions : Weight : 64 50 mm (2.0 in) ±1 mm (±0.04 in) ±2 mm (±0.08 in) Liquid crystal (both sides) and buzzer 2×AA size dry cell batteries Approx.
12. ERROR DISPLAY If an error is displayed, follow the procedures shown below. Error Display Description/Countermeasure The Height Alert Function is working. C6.2 Height Alert Function(p. 28) RL-SV2S setting exceeds the leveling range. Reset tilting to the direction to raise the X+ side. Reset tilting to the direction to raise the X- side. Alternate flashing Reset tilting to the direction to raise the Y+ side. OR Reset tilting to the direction to raise the Y- side.
12. ERROR DISPLAY Error Display Description/Countermeasure Transmission error with remote control. Change both the RL-SV2S and RC-60 to other channel. If the error persists, check the transmission environment and reduce wireless LAN and other similar wireless transmissions as much as possible. More than 2 RL-SV2S devices are within the transmission range of the RC-60, making transmission impossible. Change the channel for both the RL-SV2S (1) and RC-60 used for the operation to another channel.
12. ERROR DISPLAY Error Display E-05 E-51,55 Description/Countermeasure Turn the power for the instrument off, and then turn it back on. Internal error for the RC-60 Transmission not possible with the RL-SV2S. Remove and replace the dry cell batteries from the RC-60. Wireless function error for the RL-SV2S. Unable to transmit with the RC-60. Turn the power for the instrument off, and then turn it back on. E-56 E-65 Internal transmission error for the RL-SV2S.
13. REGULATIONS Region/ Country Directives/ Regulations Labels/Declarations FCC Compliance This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC ID: H5P-RLSV(RL-SV2S) /Contains FCC ID: H5P-RF10(RC-60) NOTE: U.S.A.
13. REGULATIONS WARNING: Change or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Specified cables must be used for connection to computer and/or peripherals in order to meet FCC emission limits. CAUTION: This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter. End user cannot modify this transmitter device.
13. REGULATIONS Region/ Country California, U.S.A.
13. REGULATIONS California, and NY, U.S.A.
13. REGULATIONS Region/ Country Directives/ Regulations Labels/Declarations IC: 6050A-RLSV (RL-SV2S) /Contains IC: 6050A-RF10(RC-60) The term “IC:” before the radio certification number only signifies that Industry Canada technical specifications were met. Canada 72 ICES “Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
13. REGULATIONS “The installer of this radio equipment must ensure that the antenna is located or pointed such that it does not emit RF field in excess of Health Canada limits for the general population; consult Safety Code 6, obtainable from Health Canada’s website www.hc-sc.gc.ca/rpb” “This device has been designed to operate with the antennas listed below, and having a maximum gain of 1.84dBi (RL-SV2S), 0.95dBi (RC-60). Antennas not included in this list or having a gain greater than 1.84dBi (RLSV2S), 0.
13. REGULATIONS Region/ Country EU Directives/ Regulations Labels/Declarations R&TTE CE R&TTE Directive EU 74 R&TTE ROTATING LASER RL-SV2S, REMOTE CONTROLLER RC-60 Hereby, TOPCON CORP., declares that the above-mentioned equipment is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. Please inquire below if you wish to receive a copy of Topcon's Declaration of Conformity. Topcon Europe Positioning B.V.
13.
This is the mark of the Japan Surveying Instruments Manufacturers Association.
http://www.topcon.co.jp Please see the attached address list or the following website for contact addresses. GLOBAL GATEWAY http://global.topcon.