Product Manual

Configuring the Receiver
PerformingaFactoryReset
53
P/N:70101004
Performing a Factory Reset
ThereceiversNonVolatileRandomAccessMemory(NVRAM)holdsdatarequiredforsatellitetracking,suchasephemerisdata
andreceiverposition.TheNVRAMalsokeepsthecurrentreceiverssettings,suchasactiveantennainput,elevationmasksand
recordinginterval,andinformationaboutthereceiversinternalfilesystem.Afactoryresetclears
thereceiversNVRAMand
restoresthereceiversfactorydefaultsettings.
AlthoughafactoryresetorclearingtheNVRAMisnotrecommendedasacommonpractice,therearetimeswhenitcan
eliminatecommunicationortrackingproblems.
Afterafactoryreset,thereceiverrequirestimetocollectnewephemeridesandalmanacs(aro und 15minutes).
Afactoryresetwillnotdeleteanyfilesalreadyrecordedinthereceiversmemory,andth eNVRAMkeepsinformationaboutthe
receiverfilesystem.
Therearetwowaysyoucanperformafactoryreset:usingTRUandusingtheLEDdisplaypanel.
UsingTRUtocleartheNVRAM:
1. Connectthereceivertoacomputer,andopenTRU.SeetheTopcon ReceiverUtility(TRU)OnlineHelpformore
information aboutconnectingthereceivertoacomputer.
2. InTRU,connecttothereceiver.