Specifications
TC6203P_D2
8 / 9
oxidation of the welding pad, and problems such as virtual welding and missed welding may
occur
during the placement process.
In order to ensure the qualified rate of reflow welding, it is recommended to extract 10% of
the
product for the first patch for visual inspection and AOI detection, so as to ensure the
rationality of
furnace temperature control, device adsorption mode and placement mode.
Operators at all stations must wear electrostatic gloves during production.
3.2 Reflow welding instructions
Figure3. TC6203P_D2 graph of reflow weldng temperature