M7 Manual V1.0
Table Of Contents
- Introduction
- Key Points
- Further information
- Safety
- Contents
- M7 Layout
- Quick start
- Charge and discharge settings
- 1. Battery type setting
- 2. The Cells Setting
- 3. Work Mode
- 4. Discharge mode
- 5. Input MaxVoltage
- 6. End voltage setting (TVC)
- 7. Current setting
- 8. NiMh setting (PeakV)
- 9. Cycle setting
- 10. External load setting
- 11. Smart battery setting
- Charge and discharge work
- Accessibility
- 3. Signal output
- 4. ESC test
- 5. Power
- System settings
- Other functions
- Specifications
@ToolkiRC 2021
33
3. Signal output
The cursor selects signal output, short press [OK],
you can enter the signal test interface.
Scroll [Scroll wheel] to select the type of signal to
be tested. Choose PWM.
Scroll the [Scroll Wheel], move the cursor to the
[Manual] item, press [OK] to set the output mode, which
can be set to manual, auto 1, auto 2, and auto 3.
When the mode is manual, you can move the
cursor to the pulse width and cycle items to set the
signal value to be output.
When set to auto 1, 2, 3, the pulse width value of
output PWM will automatically change at 3 different
speeds.
The width can be set from 800 to 2200us.