13. Technical data
Operatingvoltage .............................................9V/DC6LR61blockbattery(notincluded)
Detection depth ................................................Wood:max.20mm
ACvoltageconductor:max.50mm
Non-ferrousmetal:max.60mm
Ferrousmetal:max.80mm(variesdependingonthewallmaterial
andsizeoftheobject;thedetectiondepthisreducedforconductors
thatdonotcarryavoltage)
LCDdisplay ......................................................39x30mm
Battery life .........................................................Approx.6hours
Automatic power off ..........................................After 5 minutes
Operating/storage conditions ............................-10to+50°C,0–80%relativehumidity(non-condensing)
Dimensions(LxWxH) ....................................146x68x26.5mm
Weight ..............................................................125 g (without battery)