Certifications 2
Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau
Item no.: 1881809
Material Safety Data Sheet
11. Toxicological Information
Cells are not hazardous when used properly.
In case of fire or leakage combustion and decomposition products may cause irritation and toxicity to skin, eye and respiratory
systems.
Toxicity data of some substance is listed:
Hydrogen fluoride:
Extremely toxic, may be fatal if inhaled or ingested. Readily absorbed through the skin contact may be fatal. Possible
mutagen. LCLO: 50 ppm/30m (human beings), LC50: 1276 ppm/1h (rats).
Carbon and graphite:
Slightly hazardous in case of skin contact (irritant), ingestion, inhalation, which will cause chronic damage to upper respiratory
tract and cardiovascular system.
Copper:
Dust may cause respiratory irritation. LD50: 3.5 mg/kg (mouse).
12. Ecological Information
Some materials within the cell are bioaccumulative. Under normal conditions, these materials are contained and pose no risk
to persons or the surrounding environment.
13. Disposal Information
Recommended methods for safe and environmentally preferred disposal:
Product (waste from residues)
Do not throw out a used battery cell. Recycle it through the recycling company.
Contaminated packaging
Neither a container nor packing is contaminated during normal use. When internal materials leaked from a battery cell
contaminates, dispose as industrial waste subject to special control.
Dispose of according to all federal, state, and local regulations.
5 of 77