11. Maintenance, Servicing and Cleaning
Never use aggressive detergents, rubbing alcohol or other chemical solutions, as these could damage the
casing or stop the product from functioning properly.
• Check all parts of the swivel arm for cracks and defects after each use. The components of the swivel arm must not
show any cracks or other damage.
• Check that all the screws are tight. The vertical pipe support must be checked regularly for stability. It must not be
unstable or bent. Make sure you always pay attention to the vertical position of the 48 mm pipe support.
• Keep the retaining pins free of dust and solid impurities, such as mineral solids.
• Lubricate the retaining pin (10, 16) with grease on a regular basis.
• Use a dry, lint-free cloth to clean the product.
12. Disposal
At the end of its service life, dispose of the product in accordance with applicable regulatory guidelines.
Youthusfullyourstatutoryobligationsandcontributetotheprotectionoftheenvironment.
13. Technical Data
Load capacity at attachment point .................... 750 mm (max. 600 kg)
1100 mm (max. 300 kg)
Panning Angle ..................................................180°
Round tube (for assembly) ...............................Ø 48 mm (no included)
Dimensions (W x H x D) ..................................83.4 x 10 x 9 cm
Weight ..............................................................8.5 kg